Paradyne SLV 9128, Paradyne FrameSaver Physical, General, Network, Configuration Option, Settings

Models: Paradyne FrameSaver SLV 9128

1 19
Download 19 pages 9.64 Kb
Page 6
Image 6
General

General

Select General to configure a timeout period and duration for user-initiated loopbacks and pattern tests, a primary and secondary clock source for the system, and a system alarm relay.

General

Configuration Option

Settings

Default in [Bold]

 

 

Test Timeout

[Enable], Disable

 

 

 

Test Duration (min)

1 –120

[10]

 

 

Primary Clock Source

[Net1], DSX, Internal, DBM

 

 

Secondary Clock Source

Net1, DSX, [Internal], DBM

 

 

System Alarm Relay

Enable, [Disable]

 

 

 

Physical

Select Physical to configure the physical characteristics of each interface:

HNetwork

HData Ports

HISDN

Network

Select Network, then Physical to configure physical characteristics for the T1 network interface.

Network

Configuration Option

Settings

Default in [Bold]

 

 

 

Line Framing Format

D4, [ESF]

 

 

 

 

Line Coding Format

AMI, [B8ZS]

 

 

 

 

Line Build Out (LBO)

[0.0], –7.5, –15,

–22.5

 

 

 

Bit Stuffing

[62411], Disable

 

 

 

Transmit Timing

[System], Interface

 

 

 

Network Initiated LLB

[Enable], Disable

 

 

 

 

Network Initiated PLB

[Enable], Disable

 

 

 

Network Initiated DCLB

Disable, [V.54_&_ANSI]

 

 

 

ANSI Performance Report

Enable, [Disable]

 

Messages

 

 

 

 

Excessive Error Rate Threshold

[10E-4], 10E-5, 10E-6, 10E-7, 10E-8, 10E-9

 

 

 

Circuit Identifier

Text Field, [Clear]

 

 

 

 

6

Page 6
Image 6
Paradyne SLV 9128, Paradyne FrameSaver technical manual Physical, General, Network, Configuration Option, Settings