Paradyne Paradyne FrameSaver Data Ports, When Port Use is set to Synchronous Data on Port-2

Models: Paradyne FrameSaver SLV 9128

1 19
Download 19 pages 9.64 Kb
Page 7
Image 7
Data Ports

Data Ports

Select Data Ports, then Physical to configure physical characteristics for the port connected to the DTE.

Data Ports

Configuration Option

Settings

Default in [Bold]

 

 

 

 

Port Status

 

[Enable], Disable

 

 

 

 

 

Port Use

(Port-2 only)

[Frame Relay], Synchronous Data

 

 

 

 

 

For Port-1 or when Port Use is set to Frame Relay on Port-2:

Max Port Rate (Kbps)

[1536], 2048

(Port-2 only)

 

 

 

Invert Transmit Clock

[Auto], Enable, Disable

 

 

Transmit Clock Source

[Internal], External

 

 

Monitor DTR

[Enable], Disable

 

 

Monitor RTS (Control)

[Enable], Disable

 

 

Port (DTE) Initiated Loopback

[Disable], Local, Both

 

 

When Port Use is set to Synchronous Data on Port-2:

Port Base Rate (Kbps)

[Nx64], Nx56

 

 

Invert Transmit Clock

[Auto], Enable, Disable

 

 

Transmit Clock Source

[Internal], External

 

 

Monitor DTR

[Enable], Disable

 

 

Monitor RTS (Control)

[Enable], Disable

 

 

Port (DTE) Initiated Loopback

[Disable], DTPLB, DCLB, Both

 

 

Invert Transmit and Receive Data

Enable, [Disable]

 

 

Action on Network Yellow Alarm

None, [Halt]

 

 

Network Initiated

[Disable], V.54, ANSI_FT1, V.54_&_ANSI

Data Channel Loopback

 

 

 

7

Page 7
Image 7
Paradyne Paradyne FrameSaver Data Ports, For Port-1 or when Port Use is set to Frame Relay on Port-2, Configuration Option