ENTERING A CUSTOM PROGRAM

REMEMBER - ALL PROGRAMMING BEGINS WITH [ ldLE ] ON THE DISPLAY

Putting a program into your controller is the easiest way to understand its function.

Lets us begin with an 8 hour program. We use a slow steady rise in temperature to a maximum of 1350 °F (730 °C) in all programs (this is suggested by most investment manufacturers); then reduce the furnace temperature down to a casting temperature slowly.

Since we only have 8 hours, we will use smaller diameter flasks. We will program in 3 segments. You can program up to 20 segments if necessary.

SEGMENT 1 We will heat the furnace at a rate of 1250 °F (680 °C) per hour to a temperature of 300 °F (150 °C) and hold for 1 hour (this is our wax elimination cycle) - NOTE: OPERATOR

ATTENDANCE IS REQUIRED.

SEGMENT 2 We will then raise the furnace temperature to 1350 °F (730 °C) at a rate of 280 °F (136 °C) per hour (requires approximately 4 hours) and then hold at 1350 °F for 2 hours.

SEGMENT 3 We will then lower the furnace temperature to 900 °F (480 °C) for our casting temperature. We will program a 14 hour hold time for this temperature in case the operator is not ready to cast at the end of the 8 hour period.

NOTE: YOU CAN PROGRAM ANY FLASK CASTING TEMPERATURE YOU WISH. WE FIND THAT 900 °F IS A GOOD TEMPERATURE FOR CASTING 14K YELLOW GOLD IN MOST INSTANCES.

DELAY START: You can also delay the start of the program if you wish (see instructions following).

PROGRAMMING

1)Press keys slowly and firmly.

2)Before starting to program your controller, make sure all electrical connections are made.

3)At this time you must decide if you are going to program in °F or °C. Make sure controller is in the correct mode.

4)You can program any schedule you wish as long as it is in 20 segments or less and not over 99 hours in length.

5)The maximum temperature of the controller is 1700 °F (925 °C).

6)You can add a DELAY TIME on any program from 1 minute(00.01) to 99 hours and 99 minutes (99.99).

7)You can set the alarm on any program at any time by pressing 7 (ALARM) and

[ ALAr ] will appear on the display. Enter the new temperature and then press ENTER. [ ldLE ] will display or your program will continue the burnout in progress.

15

Page 15
Image 15
Paragon WTNFII-19, W14, W18, W13, WTNFII-10 manual Entering a Custom Program, Programming, Attendance is Required

WTNFII-10, W13, W18, W14, WTNFII-19 specifications

Paragon WTNFII-10, W14, W13, W18, and WTNFII-19 are advanced technological solutions in the realm of energy efficiency and resource management. These models exemplify innovation, efficiency, and versatility, catering to various industrial applications and operational needs.

The Paragon WTNFII-10 stands out for its robust design and high operational efficiency. It incorporates cutting-edge technologies that ensure optimal performance while minimizing energy consumption. This model is equipped with an intelligent control system that allows for real-time monitoring and adjustments, thus enhancing its suitability for dynamic environments.

The W14 model is specifically engineered for environments requiring reliable and consistent performance. Its durable construction ensures longevity while its operational features provide an edge in terms of energy savings. This model also supports integration with various automation systems, making it an ideal choice for facilities looking to streamline operations and reduce overhead costs.

Paragon's W13 is renowned for its compact design, making it perfect for installations with space constraints. Despite its size, the W13 delivers exceptional performance levels. It also features advanced filtration systems that improve air and resource quality, contributing to a healthier workspace and increasing overall productivity.

The W18 model emphasizes flexibility and adaptability. It is designed to meet the diverse needs of different industries, making it a versatile addition to any operational setup. With options for customization, the W18 can be tailored to fit specific requirements, ensuring that it meets the highest standards of performance and efficiency.

Lastly, the WTNFII-19 is a cutting-edge model that integrates the latest technological advancements. It features smart connectivity options that allow for remote monitoring and control, providing operators with greater oversight and the ability to respond swiftly to any inefficiencies or issues. Its energy-efficient design not only reduces operational costs but also contributes to sustainability goals, making it a responsible choice for modern businesses.

In summary, the Paragon WTNFII-10, W14, W13, W18, and WTNFII-19 models bring together advanced features, innovative technologies, and exceptional characteristics, making them indispensable tools for industries focused on efficiency and sustainability. Their diverse applications and ability to adapt to various operational needs underline Paragon’s commitment to providing high-quality, energy-efficient solutions for the modern era.