Paragon W14, WTNFII-19, W18, W13, WTNFII-10 manual An Operator Should Be In Attendance At All Time

Models: WTNFII-10 W13 W18 W14 WTNFII-19

1 19
Download 19 pages 49.63 Kb
Page 16
Image 16

8)REMEMBER - The furnace must be attended for the first hour so that the wax tray can be removed (the use a of Steam Wax Eliminator will eliminate this). NOTE: FOR SAFETY REASONS -

AN OPERATOR SHOULD BE IN ATTENDANCE AT ALL TIME.

9)All times are entered as follows:

For 30 minutes

Press 30

Display shows 00.30

For 1 hr. 15 min.

Press 115

Display shows 01.15

For 2 hr. 45 min.

Press 245

Display shows 02.45

* It is not necessary to put in the decimal.

Your WW Computerized Programmer uses a RAMP/HOLD method of programming. It can handle as many as 20 segments of time and temperature. Each segment raises or lowers the temperature and holds it for the length of time you specify. Most burnout programs use only 3 segments, but you have the capability of programming 20 segments.

Each segment is controlled by:

A) HEATING RATE

[ rA ]

B) TEMPERATURE

[ °F ] or [ °C ]

C) TIME

[ HD ]

In other words, furnace temperature can be brought up from ambient to 300 °F in 15 minutes or over a period of several hours. This is governed by the RATE [ rA ].

To figure the HEATING RATE, 3 variables must be considered:

1)The ending temperature desired.

2)The starting temperature.

3)The length of time that this rate should take.

For example: If we want to heat a 300 °F furnace to 1350 °F over a 6 hour period, we would calculate as follows:

ENDING TEMPERATURE (°F)

1350

 

 

STARTING TEMPERATURE (°F)

-300

 

 

DIFFERENCE (°F)

1050

 

 

DIVIDE THE TEMPERATURE DIFFERENCE

1050

1050

1050

BY THE NUMBER OF HOURS

... 6

5

3

TO GET DEGREES PER HOUR

..... .175210

350

We have illustrated above how to figure the rate for 5 hours and for 3 hours. Of course, to decrease the temperature, we would simply subtract the ending temperature from the starting temperature (in other words - reverse the procedure). Also, a decreasing rate is limited by how long it takes for a heated mass to cool when the heating elements are turned off (in other words, the larger the flask, the longer it takes to cool).

16

Page 16
Image 16
Paragon W14, WTNFII-19, W18, W13, WTNFII-10 manual An Operator Should Be In Attendance At All Time