INSTALLATION PROCEDURES FOR WW ELECTRIC BURNOUT FURNACES

1)W13 and W14 Furnaces require 240V - 20 Amp dedicated power supply and a NEMA NO: 6-20 receptacle or you can wire in direct with a breaker box nearby (USE A LICENSED ELECTRICIAN). W18 furnaces require 240V – 30 Amp dedicated power supply and a NEMA NO: 10-30 receptacle.

2)Set the furnace on a sturdy bench or table with a fire-proof top. Sides and back must be at least 12" from wall or side equipment.

3)The minimum voltage required to operate your furnace is 200V. The maximum is 250V.

4)Vent or Vents (depending on furnace model) and plug(s) are supplied for the top of the furnace. Keep vents open at all times until all fumes or vapors are eliminated. STEAM WAX ELIMINATION IS HIGHLY RECOMMENDED.

5)Read and remember the SAFETY RULES enclosed at all times.

6)Insert line cord plug into wall socket (or turn on breaker if direct wired).

a.The Controller will display all segments and the alarm sounds.

b.After a moment [ ldLE ] and the current temperature will alternately appear and the alarm will stop.

(Remember - All programming, including permanent programs, begins from [ ldLE ] ).

7)Now refer to Permanent Program No. 1 (page 10). This is the wax burnout program which is 1 - 1½ hours in length and a good system check for your controller.

Your furnace is ready for use and you have two more permanent programs available. Programs No. 2 and No. 3. One of these should be suitable for your use. If not, you may refer to "PROGRAMMING INSTRUCTIONS" and set up your own custom program (see pages 14 - 16).

Vents are built into the top of your furnace. These vents must be kept open at all times. Their purpose is to allow the fumes - created during burnout - to escape. Although not necessary, a vent hood above the furnace is a desirable asset for helping get rid of these fumes. The vent hood should be a DRAFT-TYPE vent hood, do not use a suction fan style hood, otherwise excessive power is wasted during burnout. Place top of furnace approximately 12" below vent. See illustration.

INDEX

 

Page No.

INSTALLATION INSTRUCTIONS

3-4

MISCELLANEOUS INFORMATION

5

PROGRAMMER DISPLAY & OPTIONS

6-8

SAFETY RULES, SPECIAL INSTRUCTIONS 9

PERMANENT PROGRAM NO. 1, 2,& 3

10-13

CUSTOM PROGRAM INFORMATION

14-15

PROGRAMMING STEP-BY-STEP

16

ADDITIONAL OPTIONS

17-18

A Vent Hood is recommended for burnout furnaces.

4

Page 4
Image 4
Paragon WTNFII-10, WTNFII-19, W14, W18, W13 manual Installation Procedures for WW Electric Burnout Furnaces, Index

WTNFII-10, W13, W18, W14, WTNFII-19 specifications

Paragon WTNFII-10, W14, W13, W18, and WTNFII-19 are advanced technological solutions in the realm of energy efficiency and resource management. These models exemplify innovation, efficiency, and versatility, catering to various industrial applications and operational needs.

The Paragon WTNFII-10 stands out for its robust design and high operational efficiency. It incorporates cutting-edge technologies that ensure optimal performance while minimizing energy consumption. This model is equipped with an intelligent control system that allows for real-time monitoring and adjustments, thus enhancing its suitability for dynamic environments.

The W14 model is specifically engineered for environments requiring reliable and consistent performance. Its durable construction ensures longevity while its operational features provide an edge in terms of energy savings. This model also supports integration with various automation systems, making it an ideal choice for facilities looking to streamline operations and reduce overhead costs.

Paragon's W13 is renowned for its compact design, making it perfect for installations with space constraints. Despite its size, the W13 delivers exceptional performance levels. It also features advanced filtration systems that improve air and resource quality, contributing to a healthier workspace and increasing overall productivity.

The W18 model emphasizes flexibility and adaptability. It is designed to meet the diverse needs of different industries, making it a versatile addition to any operational setup. With options for customization, the W18 can be tailored to fit specific requirements, ensuring that it meets the highest standards of performance and efficiency.

Lastly, the WTNFII-19 is a cutting-edge model that integrates the latest technological advancements. It features smart connectivity options that allow for remote monitoring and control, providing operators with greater oversight and the ability to respond swiftly to any inefficiencies or issues. Its energy-efficient design not only reduces operational costs but also contributes to sustainability goals, making it a responsible choice for modern businesses.

In summary, the Paragon WTNFII-10, W14, W13, W18, and WTNFII-19 models bring together advanced features, innovative technologies, and exceptional characteristics, making them indispensable tools for industries focused on efficiency and sustainability. Their diverse applications and ability to adapt to various operational needs underline Paragon’s commitment to providing high-quality, energy-efficient solutions for the modern era.