CPLT
DELA
minutes.
Complete This means the firing completed as programmed.
Delay DELA is a timer that starts the kiln later. Delay time appears in hours and
˚F 1 | Temperature This prompt which appears in |
a target temperature. The number is to remind you which segment will use this target temperature.
ELEC | Electronics | The Sentry circuit board is rated for operation at temperatures up to |
|
158˚F/70˚C. When the circuit gets hotter, the Sentry shuts off. The ELEC option tells you how hot the circuit board is.
ETH
Electronics Too Hot | The Sentry circuit board is too hot, so the kiln was shut off. |
FAIL | Failed The thermocouple failed. This can be due to a broken thermocouple, loose |
thermocouple connection on the back of the Sentry, disconnected thermocouple wire, or a defective controller.
FTH
all.
Failed to Heat The kiln cannot heat as fast as you programmed or is not heating at
| FTL | Firing Too Long The temperature rise is less that 27ْF/15ْC per hour and the firing |
|
| hours longer than the current segment was programmed. |
time is four |
FULL
Full Speed | The rate, or temperature change per hour, is maximum. |
Hd 1 | Temperature Hold | When this message appears during |
programming, it is asking you if you want to hold, or maintain, the target temperature of that segment. If so, enter the length of hold time in hours and minutes (i.e. 1 hour 20 minutes = 01.20). The number after Hd is the segment number. Each segment in a
| HOLd | Temperature Hold | When this message appears during programming, it is asking | ||
if you want to hold, or maintain, the target temperature. If so, enter the length of hold time in hours | |||||
and minutes (i.e. 1 hour 20 minutes = 01.20). When HOLd appears in the program review, it is | |||||
showing how much hold time has been entered. |
| ||||
|
|
|
| ||
| HtdE | High Temperature Deviation | The temperature is above the temperature deviation | ||
| setting in the | TEDE option. |
|
|
|
|
| Computer ID | The ID option is for connection the Sentry to a personal computer. | ||
| ID | ||||
|
|
|
|
| |
|
|
|
|
|
|
| IdLE | Ready to Begin The Sentry must display the idle message before you can begin firing | |||
|
| ||||
or programming. |
|
|
| ||
|
|
|
|
|
|
| LOCK | Program Lock | With this option activated, a stored program cannot be altered or | ||
|
| ||||
removed from memory. |
|
|
| ||
| LTdE | Low Temperature Deviation | This message appears when the kiln is below the |
temperature deviation setting in the TEDE option.
8