Technical Specification

ITEM

External I/O Power Supply

Requirements:

SPECIFICATION

+5VDC +/- 0.2VDC @ 2A +12VDC +/- 0.5VDC @ 0.15A -12VDC +/- 0.5VDC @ 0.15A

Note: Power consumption does not include any additional power required for external components (Encoders, Stepper Outputs, etc.).

Operating Temperature:

0°C to 50°C (32°F to 122°F)

Humidity:

0 to 95%, Non-Condensing

Size:

11” x 7” x 4.5”

See ACR1200 Hardware Manual for controller Technical Specification.

32

OPS1200 User’s Manual

Page 38
Image 38
Parker  Products OPS1200 user manual Technical Specification