TECHNICAL DATA
DIMENSIONS
| Height | Width | Depth |
Height to hotplate | 900mm (nominal) | 600mm (nominal) | 600mm |
|
|
| (to front of |
|
|
| door panel) |
Space for fixing at hotplate level | 2mm minimum clearance |
|
|
Space for fixing above hotplate level | |||
Minimum space above hotplate | 787mm (If a cooker hood is fitted refer to the cooker hood | ||
| installation instructions). |
|
|
Weight of appliance | 64.5kg. |
|
|
Minimum distance from rear wall | 5mm (spacer given by pressed spacer on vent panel). |
CONNECTIONS
Gas | Rear left hand side of appliance at hotplate level. | |||
| Rc½ (½" B.S.P. female). |
|
| |
Electric | ||||
| moulded plug fitted with a 3 amp fuse. |
| ||
GRILL | Natural Gas |
| L.P.Gas |
|
Heat Input | 2.7kW (9215 Btu/h) | 2.45kW (176 g/h) | ||
Injector Marking | 121 |
| 078 |
|
HOTPLATE |
| Natural Gas |
| |
| R.H.F. | R.H.R. | L.H.R. | L.H.F |
Heat Input | 1.0kW | 1.9kW | 1.9kW | 2.9kW |
| (3412 Btu/h) | (6483 Btu/h) | (6483 Btu/h) | (9895 Btu/h) |
Injector Marking | 070 | 096 | 096 | 119 |
|
| L.P.Gas |
| |
| R.H.F. | R.H.R. | L.H.R. | L.H.F. |
Heat Input | 1.0kW | 1.9kW | 1.9kW | 2.9kW |
| (71.85 g/h) | (136.5 g/h) | (136.5 g/h) | (208.4 g/h) |
Injector Marking | 050 | 071 | 071 | 083 |
44