TECHNICAL DATA

DIMENSIONS

 

Height

Width

Depth

Height to hotplate

907mm (nominal)

500mm (nominal)

603 mm

 

 

 

(to front of

 

 

 

door panel)

Space for fixing at hotplate level Minimum space above hotplate

Space for fixing above hotplate level Weight of appliance

Minimum distance from rear wall

2mm minimum clearance

787mm (If a cooker hood is fitted refer to thecookerhood installation instructions).

See important note "Location of Appliance", page 37. 48.4kg.

5mm (spacer given by pressed spacer on vent panel).

CONNECTIONS

Gas

Rear left hand side of appliance at hotplate level.

 

Rc½ (½" B.S.P. female).

Electric

None

IGNITION

Spark generator

APCO 7BG 6893

Battery

1.5 Volt AA size

GRILL

 

Natural Gas

 

L.P. Gas

 

Heat Input

3.3kW (11263 Btu/h)

3.0kW (215g/h)

 

Injector Marking

138

 

88

 

 

HOTPLATE

 

Natural Gas

 

 

R.H.F.

R.H.R.

 

L.H.R.

L.H.F

Heat Input

1.0kW

2.0kW

 

2.0kW

2.8kW

 

(3412 Btu/h)

(6824 Btu/h)

( 6824 Btu/h)

(9554 Btu/h)

Injector Marking

079

104

 

104

130

 

 

L.P.Gas

 

Heat Input1

1.0kW

2.0kW

 

2.0kW

2.7kW

 

(71.8 g/h)

(143.7 g/h)

(143.7 g/h)

(194.0 g/h)

Injector Marking

051

072

 

072

083

35

Page 35
Image 35
Parkinson Cowan SONATA 50GX installation instructions Dimensions, Connections, Ignition, Grill