3.1.1 CONFIGURATION SWITCH PACK “S1”

3.1.1 CONFIGURATION SWITCH PACK “S1”

The eight DIP switches on pack S1 set Remote Test Activation and RTS/CTS Delay. Descriptions of all possible S1 switch settings, including the Patton factory default settings, are found on on pages 4 and 5.

S1 SUMMARY TABLE

Position

Function

Factory Default

 

 

 

 

 

 

S1-1

DTE Control of LAL

On

Enabled

 

 

 

 

 

S1-2

DTE Control of RDL

On

Enabled

S1-3

Not Used

Off

}

 

 

S1-4

Not Used

Off

N/A

S1-5

Not Used

Off

 

 

S1-6

Not Used

Off

 

 

S1-7

RTS/CTS Delay

Off

} 0 mS

S1-8

RTS/CTS Delay

Off

Figure 3. Summary of DIP switch default settings for set S1

S1-1: DTE Control of LAL

The setting for switch S1-7 determines whether the Local Analog Loopback test on the Model 1018RC can be activated via pin 18 of the RS-232 interface.

S1-1

Setting

On

Enabled

Off

Disabled

S1-2: DTE Control of RDL

The setting for switch S1-7 determines whether the Remote Digital Loopback test on the Model 1018RC can be activated via pin 21 of the RS-232 interface.

S1-2

Setting

On

Enabled

Off

Disabled

S1-3 through S1-6: Not Used

S1-7 and S1-8: RTS/CTS Delay

The combined settings for switches S1-7 and S1-8 determine the amount of delay between the time the Model 1018RC “sees” RTS and when it sends CTS. Currently, the Model 1018RC does not have optional delay settings. “No Delay” is defined as between 500 nsec and 1 msec. The switches should remain in the “OFF” position.

S1-7

S1-8

Setting

Off

Off

0 mS delay

 

 

No other valid settings

3.1.2 CONFIGURATION SWITCH SET “S2”

The eight DIP switches on pack S2 set Digital Reset, Carrier Control, Link Clocking, Async Data Rate and Microprocessor Reset. Factory default settings are summarized in Figure 4, below. Descriptions of all possible S1 switch settings, including the Patton factory default settings, are found on on pages 6 and 7.

S2 SUMMARY TABLE

Position

Function

Factory Default

 

 

 

 

 

 

 

S2-1

V.54 Disable

Off

 

Normal

 

 

 

 

 

S2-2

Control of Carrier

On

Ctrl by DTR

 

 

 

 

 

 

S2-3

Link Clocking

On

} Internal

S2-4

Link Clocking

On

S2-5

Async Data Rate

On

}

 

 

S2-6

Async Data Rate

On

57.6 Kbps

S2-7

Async Data Rate

On

 

 

 

 

 

 

 

 

S2-8

Microprocessor Reset

Off

 

Normal

Figure 4. Summary of DIP switch default settings for S2

5

6

Page 4
Image 4
Patton electronic 1018RC CONFIGURATION SWITCH PACK “S1”, S1 SUMMARY TABLE, S1-1 DTE Control of LAL, S2 SUMMARY TABLE