SYMPTOM
APPENDIX A
TROUBLESHOOTING
PROBLEMSOLUTION
SYMPTOM | PROBLEM | SOLUTION |
Data passes, but | Incorrect DIP switch | Switch 7 must be in the |
hardware flow | setting | ON condition for |
control doesn’t |
| hardware flow control |
LEDs do not light when AC power transformer is plugged into wall
Carrier Detect (CD) LED is low
or
Carrier Detect (CD) LED is high, but
Loose power connection
Outlet is defective
AC power cord is defective
AC transformer is not plugged into the Model 1180
If CD is low, possible synchronization loss
Make sure the AC connection is flush
Try a different outlet
Remove the cord from the outlet and check for continuity
Plug transformer into Model 1180
Check for ongoing power loss or break in fiber if CD does not go high within 60 seconds
work |
| signals to pass |
|
| between Model 1180s; |
|
| both units must be set |
|
| the same way |
Model 1180s work | Incorrect DIP switch | Switch 8 (internal/ |
in async. mode, | setting | external clock) must be |
but not sync. mode |
| set the same way for |
|
| both Model 1180s |
1180s are not communicating
Test Mode switch is in | Make sure the Test |
the wrong position | Mode switch is set to |
| NORMAL on both |
| Model 1180s |
DIP switches are set improperly
Check all DIP switch settings, esp. Reset and Data Rate, against Section 3; make sure both Model 1180s are configured the same way
Fiber link is connected improperly
Check the ST or SMA connection on the back of both Model 1180s
Check