APPENDIX A
PATTON ELECTRONICS G.703/G.704 SDSL MODEM
SPECIFICATIONS
Clocking Modes: | Network (G.703/G.704), Internal, Receive |
| Recover |
Line Rate: | 2048 kbps |
Diagnostics: | V.52 compliant (511/511E) pattern generator |
| and detector with error injection mode. |
| Remote Loopback (toward fiber line) and |
| local loopback (toward G.703/G.704 Net- |
| work) controlled by a single front panel |
| switch |
LED Status: | The following LEDs are displayed on the |
| front panel: |
| Fiber: The green Fiber LED indicates reli- |
| able data on the fiber side |
| E1: The green E1 LED indicates reliable |
| data on the G.703/G.704 side |
| LOS: The red LOS indicates that syncro- |
| nization between modems has not been |
| established. Blinking red LOS LED indicates |
| the presense of coding errors. |
| NS: The red NS LED indicates that the sig |
| nal on the fiber side is too weak to be |
| detected. |
| ER: Flashing red ER LED indicates errors in |
| 511 test pattern |
| TM: The yellow TM LED indicates that |
| modem is in a test mode |
| (Local/Remote Loopback or 511/511E test |
| pattern). Opaque TM LED indicates normal |
| operation. |
Configuration: | Externally accessible dip switches |
Power: | 5 VDC from external desk top power supply, |
| |
| Input), 10W or |
Compliance: | FCC Part 15, CE, CTR12 |
Transmission Line: | Single fiber |
Line Coding: | 8B10B |
Line Interface: | Transformer coupled, 1500 VAC isolation |
Fiber Physical |
|
Connection: | One string of 9/125 micron fiber with FC |
| or SC connectors |
| G.703/G.704 Specific |
Interface: | Female Dual Coaxial 75 ohm or |
| Female |
Line rate: | 2.048 Mbps |
Line coding: | AMI or HDB3 (HDB3 is the default) |
Isolation: | 1500 Vrms |
Physical Connection: | pin 1 Rx Data + |
pin 2 Rx Data - | |
| pin 4 Tx Data + |
| pin 5 Tx Data - |
| pins 3, 6, 7, 8 no connection |