Completing the installation 47
Model 2960/2996 RAS User Manual 3 • Configuring the RAS for operation
To save the displayed data as a text file, select the Save option on your browser (see figure 36). For example,
under Netscape, select File
>
Save As. A dialog box will display enabling you to save the contents of the export
parameters to a text file. Select the location where you want the file stored, type a file name, and click Save.
Figure 36. Saving the access server flash memory configuration data as a text file
Completing the installation
This section verifies that the RAS is fully operational.
1. Temporarily disconnect the male ends of both power cords from the power outlet. Wait 30 seconds, then
plug the power cords in again.
2. Verify that the green POWER LED is lit. If the POWER LED is flashing green, refer to Chapter 5, “Trou-
bleshooting and maintenance”.
3. Verify that the Link 1 Frame LED illuminates, indicating that the RAS is synchronizing with the T1/E1/
PRI signal.
4. Verify that after 5 seconds, the Link A Error LED begins flashing, indicating that the RAS is satisfied with
the quality of the T1/E1/PRI signal.
5. Verify that after 10 seconds, the Link A Error LED extinguishes, indicating that the RAS is satisfied with
the network signal and that the link is ready for use.