Peavey 3000, 4000, 4080 owner manual Wire Guage Charts

Models: 3000 4000

1 56
Download 56 pages 24.62 Kb
Page 10
Image 10

Wire Guage Charts

Stranded Cable Lgth.

Wire Gauge (AWG)

Power Loss

Power Loss

Power Loss

(ft.)

 

(8 ohm load)

(4 ohm load)

(2 ohm load)

5

18

0.81%

1.61%

3.2%

 

16

0.51

1.02

2.0

 

14

0.32

0.64

1.28

 

12

0.20

0.40

0.80

 

10

0.128

0.25

0.51

 

 

 

 

 

10

18

1.61%

3.2%

6.2%

 

16

1.02

2.0

4.0

 

14

0.64

1.28

2.5

 

12

0.40

0.80

1.60

 

10

0.25

0.51

1.01

 

 

 

 

 

40

18

6.2%

11.9%

22%

 

16

4.0

7.7

14.6

 

14

2.5

5.0

9.6

 

12

1.60

3.2

6.2

 

10

1.01

2.0

4.0

 

8

0.60

1.20

2.4

 

 

 

 

 

 

18

11.9%

22%

37%

80

16

7.7

14.6

26

 

14

5.0

9.6

17.8

 

12

3.2

6.2

11.8

 

10

2.0

4.0

7.7

 

8

1.20

2.4

4.7

Stranded Cable Lgth.

Wire Gauge (mm2)

Power Loss

Power Loss

Power Loss

(m)

 

(8 ohm load)

(4 ohm load)

(2 ohm load)

 

 

 

 

 

2

0.3

2.9%

5.6%

10.8%

 

0.5

1.74

3.4

6.7

 

0.75

1.16

2.3

4.5

 

1.5

0.58

1.16

2.3

 

2.5

0.35

0.70

1.39

 

4

0.22

0.44

0.87

 

 

 

 

 

5

0.5

4.3%

8.2%

15.5%

 

0.75

2.9

5.6

10.8

 

1.5

1.45

2.9

5.6

 

2.5

0.87

1.74

3.4

 

4

0.55

1.09

2.2

 

6

0.37

0.73

1.45

 

 

 

 

 

10

0.5

8.24%

15.5%

28%

 

0.75

5.6

10.8

19.9

 

1.5

2.9

5.6

10.8

 

2.5

1.74

2.9

6.7

 

4

1.09

1.74

4.3

 

6

0.73

1.09

2.9

 

 

 

 

 

30

0.75

15.5%

25%

45%

 

1.5

8.2

15.5

28

 

2.5

5.1

9.8

18.2

 

4

3.2

6.3

12.0

 

6

2.2

4.3

8.2

 

10

1.31

2.6

5.1