Peavey CKS Series, CKV Series Signal Ground Lift Jumper, Replacing or Installing a Network Module

Models: CKX Series CKS Series CKV Series

1 20
Download 20 pages 25.56 Kb
Page 10
Image 10

Input Module Replacement Diagram - NC-IPN.

Designed & manufactured in the USA by:

 

 

 

 

 

 

 

Crest Audio Inc.

 

 

 

WIRING

 

 

100 Eisenhower Dr.

 

 

USED

 

 

Paramus, New Jersey 07652 USA

t

Model

Output Power

Model

Output Power

 

Name

@70.7V

Name

@8Ω/Ch.

 

 

CKV 100

50W

CKS 100

 

50W

 

 

CKV 200

100W

CKS 200

 

100W

 

 

CKV 400

200W

CKS 400

 

200W

 

 

CKV 800

400W

CKS 800

 

400W

 

 

CKS 800-2

 

400W

 

CKV 1600

800W

CKS 1200-2

 

600W

 

CKV 2400

1200W

CKS 1600-2

 

800W

 

 

Network

 

Address

Model

 

 

 

Data

F

F

NC-NXS

 

 

 

 

 

ED

ED

 

 

 

5

 

5

 

 

 

 

67

 

67

 

+

+ –

 

Hi

Lo

 

Ribbon Cable from

Network Module, if fitted

SEE INSTRUCTION MANUAL

 

 

 

Level

4

5

6

N-Coder

 

 

A

3

 

7

Data

 

 

2

 

 

8

Port

 

 

1

 

 

9

 

 

 

 

0

 

10

 

 

 

Level

4

5

6

Input A

 

Input B

B

3

 

7

+

+

2

 

 

8

1

 

 

9

 

 

 

 

0

 

10

 

 

 

Model

 

 

 

 

 

 

NC-IPN

 

 

 

Replacing or Installing a Network Module.

The amplifier must be switched off and unplugged from the AC mains supply before this operation is undertaken. Four Phillips head screws secure the module to the chassis. The module is connected electrically to the amplifier via multi-pin ribbon cables. Unplugging the module from the ribbon cable connectors frees the module for removal. To insert the same or another module, simply reverse this procedure. Note: Standard CK Power Processing amplifiers come with a blank panel installed in the Network bay. The amplifier must not be operated without a Network module or blank panel in place.

IMPORTANT:

THE POWER/OUTPUT

MODULE IS NOT REMOVABLE. DO NOT ATTEMPT TO REPLACE OR REMOVE A POWER/OUTPUT MODULE !

This module can only be serviced by a Crest Audio-certified service technician. Please consult your dealer or Crest Audio representative for assistance. User-inflicted damage to this module will invalidate your warranty.

Signal Ground Lift Jumper.

Whenever possible, the signal source equipment should share the same AC ground as the amplifier(s). In some cases, however, partic- ularly if an amplifier is being installed in an existing system, this may result in a ground loop. If this happens, remove the factory- installed ground lift jumper from the output barrier strip (located on the Power/Output module), which electrically connects the signal ground to the chassis/AC ground. If the jumper is removed, the sig- nal ground is lifted and is clamped to ± 0.6V. Don’t remove the jumper if the amplifier and the signal source equipment are not on the same AC ground!

In a properly designed system (for safety and to minimize noise), the amplifier should receive its ground from the AC line cord. The shield

Network Module Installation Diagram.

CLASS 2 WIRING

MAY BE USED

Output

+8 to 18VDC

20 mA

 

A

+

+

B

NEC

LASS 2 ONLY

Signal

Ground

Lift

Jumper

Model

CC-STL

Designed & manufactured in the USA by:

 

 

 

 

 

 

 

 

 

 

Crest Audio Inc.

 

 

 

 

 

 

 

 

 

100 Eisenhower Dr.

 

 

 

 

 

 

Paramus, New Jersey 07652 USA

Model

Output Power

Model

Output Power

Name

@70.7V

Name

 

@8Ω/Ch.

CKV 100

50W

CKS 100

 

 

 

50W

 

 

CKV 200

100W

CKS 200

 

 

100W

 

 

CKV 400

200W

CKS 400

 

 

200W

 

 

CKV 800

400W

CKS 800

 

 

400W

 

 

CKS 800-2

 

 

400W

 

 

CKV 1600

800W

CKS 1200-2

 

 

600W

 

 

CKV 2400

1200W

CKS 1600-2

 

 

800W

 

 

Network

 

 

Address

 

Model

 

 

Data

 

0

F E

1 0

 

NC-NXS

 

 

1

F E

 

 

 

3

 

 

D

3

 

D

 

 

 

45

 

 

C

45

 

C

 

 

 

6

 

 

B

6

 

B

 

 

 

7

8

9

 

78

9

 

+ –

+ –

 

Hi

 

Lo

PUSH

SEE INSTRUCTION M

N-Coder

 

Data

 

Port

 

Error

 

AES/EBU

Inp

In

 

+

on a balanced input line should be grounded at one end only (usually the sending end), and it must never be relied on to supply AC ground to the amplifier.

+8 to 18VDC

 

 

240 mA

 

A

 

 

 

+

Signal Ground

In

Lift Jumper

 

 

Out

+

 

Com

 

 

 

NEC

 

B

 

 

CLASS 2 ONLY

 

 

 

 

Signal

 

 

Ground

 

 

Lift

 

 

Jumper

Model

 

 

CC-STL

 

 

Page 8

Crest Audio CK Power Processing Amplifiers