Peavey CS 4000, CS 4080 owner manual Kabelstärkentabellen, Stranded Cable Lgth

Models: CS 4080 CS 4000

1 52
Download 52 pages 24.88 Kb
Page 20
Image 20
Kabelstärkentabellen

Kabelstärkentabellen

Stranded Cable Lgth.

Wire Gauge (AWG)

Power Loss

Power Loss

Power Loss

(ft.)

 

(8 ohm load)

(4 ohm load)

(2 ohm load)

5

18

0.81%

1.61%

3.2%

 

16

0.51

1.02

2.0

 

14

0.32

0.64

1.28

 

12

0.20

0.40

0.80

 

10

0.128

0.25

0.51

 

 

 

 

 

10

18

1.61%

3.2%

6.2%

 

16

1.02

2.0

4.0

 

14

0.64

1.28

2.5

 

12

0.40

0.80

1.60

 

10

0.25

0.51

1.01

 

 

 

 

 

40

18

6.2%

11.9%

22%

 

16

4.0

7.7

14.6

 

14

2.5

5.0

9.6

 

12

1.60

3.2

6.2

 

10

1.01

2.0

4.0

 

8

0.60

1.20

2.4

 

 

 

 

 

 

18

11.9%

22%

37%

80

16

7.7

14.6

26

 

14

5.0

9.6

17.8

 

12

3.2

6.2

11.8

 

10

2.0

4.0

7.7

 

8

1.20

2.4

4.7

Stranded Cable Lgth.

Wire Gauge (mm2)

Power Loss

Power Loss

Power Loss

(m)

 

(8 ohm load)

(4 ohm load)

(2 ohm load)

 

 

 

 

 

2

0.3

2.9%

5.6%

10.8%

 

0.5

1.74

3.4

6.7

 

0.75

1.16

2.3

4.5

 

1.5

0.58

1.16

2.3

 

2.5

0.35

0.70

1.39

 

4

0.22

0.44

0.87

 

 

 

 

 

5

0.5

4.3%

8.2%

15.5%

 

0.75

2.9

5.6

10.8

 

1.5

1.45

2.9

5.6

 

2.5

0.87

1.74

3.4

 

4

0.55

1.09

2.2

 

6

0.37

0.73

1.45

 

 

 

 

 

10

0.5

8.24%

15.5%

28%

 

0.75

5.6

10.8

19.9

 

1.5

2.9

5.6

10.8

 

2.5

1.74

2.9

6.7

 

4

1.09

1.74

4.3

 

6

0.73

1.09

2.9

 

 

 

 

 

30

0.75

15.5%

25%

45%

 

1.5

8.2

15.5

28

 

2.5

5.1

9.8

18.2

 

4

3.2

6.3

12.0

 

6

2.2

4.3

8.2

 

10

1.31

2.6

5.1

20

Page 20
Image 20
Peavey CS 4000, CS 4080 owner manual Kabelstärkentabellen, Stranded Cable Lgth