Installation to Concrete Ceilings

Installation to Concrete Ceilings

WARNING

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard- ware and components.

3

Place projector mount assembly (A) on ceiling as a

 

 

template and mark the center of the two mounting

 

 

 

holes. Drill two 1/4" (6 mm) dia. holes to a minimum

 

 

 

depth of 2.5" (64 mm). Attach projector mount

 

 

 

assembly (A) using two concrete anchors (G), two

 

 

 

flat washers (E), and two #14 x 2.5" wood screws

 

 

 

(F) as shown.

 

 

 

NOTE: Mounting slots on projector mount assembly

 

 

 

allow for 30° (±15°) of rotation before fully securing

 

 

 

wood screw.

 

 

 

Tighten wood screws (F) using 3/8" (10 mm) socket

G

 

 

wrench or phillips screwdriver until projector mount

 

 

assembly (A) is firmly attached.

 

FRONT OF

 

 

 

 

Skip to step 5.

A

MOUNT

 

WARNING

 

 

E

 

Tighten wood screws firmly, but do not overtighten.

 

 

Overtightening can damage the screws, greatly re-

F

 

 

ducing their holding power.

 

 

 

 

• Never tighten in excess of 80 in • lb (9 N.M.).

WARNING

1

surface

 

 

concrete

• Always attach concrete anchors directly to load-

 

G

bearing concrete.

 

Never attach concrete anchors to concrete covered

Drill holes and insert anchors (G).

 

 

 

with plaster, drywall, or other finishing material. If

 

 

 

 

 

 

A

 

 

 

mounting to concrete surfaces covered with a finish-

2

 

 

 

ing surface is unavoidable (not evaluated by UL), the

 

 

 

finishing surface must be counterbored as shown be-

 

 

 

 

 

low. Be sure concrete anchors do not pull away from

 

F

G

 

 

concrete when tightening screws. If plaster/drywall is

 

 

 

thicker than 5/8", custom fasteners must be supplied

Place plate (A) over anchors (G) and secure with screws (F).

 

by installer (not evaluated by UL).

 

 

 

 

 

3

 

 

 

 

 

INCORRECT

CORRECT

 

 

 

 

 

 

 

 

 

 

 

VIEW

A

concrete

A

concrete

 

 

 

 

CUTAWAY

 

plaster/

plaster/

 

Tighten all fasteners.

 

 

 

 

 

 

 

 

 

 

 

drywall

drywall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 of 13

 

ISSUED: 08-15-07 SHEET #: 055-9188-6

06-25-10

Visit the Peerless Web Site at www.peerlessmounts.com

For customer care call 1-800-865-2112 or 708-865-8870.

Page 6
Image 6
Peerless Industries PRS-1S, PRS-1W manual Installation to Concrete Ceilings, Incorrect, Correct, 6 of, Cutaway