Installation to Solid Concrete or Cinder Block

Installation to Solid Concrete or Cinder Block

concreteWARNING

When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.

3

Make sure that wall plate (F) is level, use it as a

 

solid

 

 

 

 

template to mark the two center mounting holes. Drill

K

concrete

 

 

 

 

two 1/4" (6 mm) dia. holes to a minimum depth of 2.5"

 

cinder

 

 

 

(64 mm). Insert anchors (K) in holes flush with wall as

F

 

 

block

 

 

shown. Place wall plate over anchors and secure with

 

 

 

 

 

#14 x 2.5" screws (J). Level, then tighten all fasteners.

 

 

 

 

 

 

 

WARNING

 

J

 

 

 

 

 

Tighten screws so that wall plate is firmly attached,

 

 

 

 

 

 

 

but do not overtighten. Overtightening can damage

 

 

 

 

 

 

 

screws, greatly reducing their holding power.

 

 

 

 

 

 

 

Never tighten in excess of 80 in. • lb (9 N.M.).

 

 

 

 

 

 

 

 

WARNING

 

1

 

 

 

concrete

 

 

 

 

 

 

 

 

 

 

 

 

surface

 

 

 

 

 

 

 

 

 

 

 

Always attach concrete anchors directly to load-

 

 

 

 

 

K

 

 

bearing concrete.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Never attach concrete anchors to concrete covered

 

 

 

 

 

 

 

with plaster, drywall, or other finishing material. If

 

Drill holes and insert anchors (K).

 

 

 

 

mounting to concrete surfaces covered with a finishing

2

 

F

 

 

 

 

surface is unavoidable, the finishing surface must be

 

 

 

 

 

counterbored as shown below. Be sure concrete

 

 

 

 

 

 

 

anchors do not pull away from concrete when tighten-

 

 

 

 

 

 

 

ing screws. If plaster/drywall is thicker than 5/8",

 

 

 

J

 

K

 

 

custom fasteners must be supplied by installer.

 

 

 

 

 

 

INCORRECT

 

CORRECT

 

Place plate (F) over anchors (K) and secure with screws (J).

 

 

 

3

 

 

 

 

 

VIEW

 

 

 

 

 

 

 

 

 

wall plate

concrete

wall plate

concrete

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CUTAWAY

plaster/

 

plaster/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

drywall

 

drywall

 

 

 

 

 

 

 

 

 

 

 

 

Tighten all fasteners.

 

 

 

 

 

 

 

 

7 of 24

 

ISSUED: 08-27-07 SHEET #: 083-9007-2

07-09-08

Visit the Peerless Web Site at www.peerlessmounts.com

 

For customer care call 1-800-865-2112 or 708-865-8870.