Pelco 100BASE-FX, 100BASE-TX manual Mounting, MOUNTING THE FX82052 MODULE INTO A RACK

Models: 100BASE-TX 100BASE-FX

1 40
Download 40 pages 32.31 Kb
Page 18
Image 18

MOUNTING

The FX82052 module can be mounted into a rack or can be used as a stand-alone module. As a stand- alone module, the unit can be placed on a desktop or can be mounted to a wall.

NOTE: As a matter of convenience, it is recommended that you set the modes of operation for each 10BASE-T/100BASE-TX port and the fiber failover mode—if required—before mounting the FX82052 module into a rack or onto a wall. For information about setting the 10BASE-T/100BASE-TX port modes of operation, refer to Setting 10BASE-T/100BASE-TX Port Modes of Operation on page 14. For information about setting the fiber failover mode, refer to Setting Fiber Failover Mode on page 16.

MOUNTING THE FX82052 MODULE INTO A RACK

The FX82052 module can be installed into an RK5000 Series rack mount chassis, which can be mounted into an industry-standard 19-inch (48.26 cm) equipment rack. The RK5000 Series rack mount chassis includes the following models:

RK5000PS-3U and RK5000-3U:Designed to accommodate fiber optic modules as follows:

The RK5000PS-3U rack mount chassis provides 12 single-width module slots and a power supply.

The RK5000-3U rack mount chassis provides 14 single-width module slots (a power supply is not included). Power to the modules can be supplied using the optional external power supply (EPS5000-120).

For additional information, refer to the RK5000PS-3U/RK5000-3U Fiber Rack Mount Chassis Installation manual.

RK5000PS-5U:Designed to accommodate Enduramodules but can also accommodate fiber optic modules with the use of the appropriate adapter kit. The RK5002-1UEXP adapter kit is required for installation of the FX82052 module into the RK5000PS-5U chassis.

For information about the RK5000PS-5U chassis, refer to the RK5000PS-5U Rack Mount Chassis Installation manual.

NOTE: The FX82052 module is a double-width fiber optic module that occupies two slots in the RK5000PS-3U, RK5000-3U, and RK5000PS-5U chassis.

MOUNTING THE FX82052 MODULE TO A WALL

The FX82052 module can be mounted to a wall in the following ways:

Using the supplied wall clip for attachment of a single module to a wall. For installation instructions, refer to Mounting the FX82052 Module Using the Wall Clip on page 19.

Using the optional WM5002 wall mount kits, which are designed for mounting of double- width fiber optic modules. The WM5002-3U base kit allows mounting of a single module to a wall. The WM5002-3UEXP expansion kit allows mounting of an additional module. It is recommended that a maximum of one expansion kit be used with the base kit, allowing a maximum of two double-width modules to be mounted to a wall.

NOTE: The WM5002 wall mount kits can be used with the WM5001 wall mount kits, which are designed for mounting of single-width fiber optic modules. If mounting a mix of single-width and double-width modules is desired, it is recommended that a maximum of two single-width modules and one double-width module be mounted in combination with one another.

For mounting instructions using the wall mount kits, refer to the WM5000 Series Wall Mount Kit Installation manual.