INSTALLATION TO THE SURFACE OF A 4S STANDARD ELECTRICAL BOX

Refer to Figure 7 and complete the following steps.

1.Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied).

2.Connect the video cable/wires.

BNC: Connect the BNC connector from the Camclosure to a mating BNC connector.

Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -.

3.Connect the power wires.

Table D. Power Input: 4S Standard Electrical Box Installation

Voltage

Red Wire

Black Wire

 

 

 

12 VDC

+

Ground

 

 

 

24 VAC

~

~

 

 

 

AC Operation Only: If you are wiring more than one ICS090 Camclosure to the same transformer, connect one side of the transformer to the red wire on all units, and then connect the other side of the transformer to the black wire on all units. Failure to connect all of the units in the same way will cause the cameras to be out of phase with each other, which might produce a vertical roll when switching between cameras.

4.Attach the surface trim ring and back box to the adapter plate with the two 8-32 x 2.50-inch screws (supplied).

4S STANDARD ELECTRICAL BOX

CEILING/

WALL

8-32 X 1.00

(SUPPLIED) OPTIONAL ADAPTER RING

8-32 X 2.50

BACK BOX AND

(SUPPLIED)

SURFACE MOUNT

 

RING

Figure 7. 4S Standard Electrical Box Installation