INSTALLATION IN A 4S DEEP ELECTRICAL BOX

Refer to Figure 8 and complete the following steps.

1.Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following steps:

a.Place your fingers on the circular marks located on the sides of the surface mount ring.

b.Pinch the sides.

c.Lift and remove the surface mount ring from the back box.

2.Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied).

3.Connect the video cable/wires.

BNC: Connect the BNC connector from the Camclosure to a mating BNC connector.

Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -.

4.Connect the power wires.

Table E. Power Input: 4S Deep Electrical Box Installation

Voltage

Red Wire

Black Wire

 

 

 

12 VDC

+

Ground

 

 

 

24 VAC

~

~

 

 

 

AC operation only: If you are wiring more than one ICS090 Camclosure to the same transformer, connect one side of the transformer to the red wire on all units, and then connect the other side of the transformer to the black wire on all units. Failure to connect all of the units in the same way will cause the cameras to be out of phase with each other, which might produce a vertical roll when switching between cameras.

5. Attach the back box to the adapter plate with the two 8-32 x 0.750-inch screws (supplied).

4S DEEP ELECTRICAL BOX

CEILING/

WALL

8-32 x 1.00

ADAPTER

RING

(SUPPLIED)

 

8-32 X .750

BACK

(SUPPLIED)

BOX

Figure 8. 4S Deep Electrical Box Installation

14

C2462M-D (3/08)

Page 14
Image 14
Pelco 90 manual Installation in a 4S Deep Electrical BOX, Deep Electrical Box Installation