24 Pelco Manual C1043M-A (2/96)
8.0 POWER-UP PROCEDURE FOR THE
ICI3000P
In the ev ent of a power f ailure, the Inter-Check System
has a nonvolatile memory and will retain all memory
that has been previously saved. Some program func-
tions, in order to be used, will have to be activated us-
ing the hot keys.
Following is a po wer-up procedure checklist to be fol-
lowed in the event that the Inter-Check system experi-
ences a power outage.
1. Check all cables (power, video, data, alarm, etc.);
make sure all connections are intact.
2. Power down and then power up the ICI3000P to
make sure system defaults have loaded and initial-
ized correctly.
3. Turn on the “Auto Camera” feature by pressing
[F12] or by pressing [Enter] from the select
menu and [6] to select Auto Camera ON. T urn the
video ON if the monitor is blank by pressing [P]
while in the Monitoring mode. Then press [F9]
again followed the camera in the Shadow List that
you wish to view.
4. Poll the ICI1000PIM units to make sure that they
are communicating by pressing [P] while in the
Monitoring mode. Then press [I] to initialize the
poll. If some units do not answer , check all system
cables for loose connections.
5. Check all programming to confirm that the memory
was retained. T o reenter any programming that may
have been lost, make sure that the NV switch on
the underside of the ICI3000P unit is in the “un-
locked” position (i.e., away from the BNC con-
nectors on the back of the unit. Lock the NV switch
when programming is complete.
6. Execute a “System Save” to retain programming
information. To exit out of the Monitoring Mode,
press “Enter”. Select the Menu and press [0] to
save.
7. To reactivate the functions you need, use the Hot
Key Summary List on page 19 of the ICI3000P
manual. Press the corresponding Function Keys
(“S” to sequence, for example), while in the Moni-
toring Mode.