36 C1566M-C (10/05)
VERIFY SYSTEM OPERATION
1. Power up all the remaining equipment.
2. After the CM9700-CC1 loads the configuration files, “SYSTEM 97XX” appears on the CM9760-KBD LCD.
3. Enter the default operator password on the CM9760-KBD keypad. “ENTER MONITOR #” appears on the LCD.
4. Enter 1, and then press the MON key. (Note: if you are not viewing monitor 1, substitute the appropriate monitor number.)
5. Enter a camera number, and then press the CAM key.
6. Press the FWD key to step through cameras and verify switching.

INITIALIZE KEYBOARDS

Specify a monitor for each keyboard after your first power-up or any time power is cycled to the keyboard or the CM9700-CC1.
Always allow five seconds to elapse before specifying a monitor.
1. Enter a number corresponding to the monitor output that is feeding the monitor you are viewing.
2. Press the MON key. The keyboard LED displays the number you entered. This also confirms successful communication between the
keyboard and the CM9700-CC1. If the keyboard LED does not display the monitor number, repeat steps 1 and 2.

DISPLAY THE CM9780-MXB SOFTWARE VERSION LEVEL

To display the software version level on a system monitor, complete the following steps:
1. Enter the monitor number, and then press the MON key.
2. Enter 999997, and then press the CAM key. The software version number appears on the monitor.

DISPLAY A BLUE RASTER SCREEN

To display a blue raster screen on a system monitor, complete the following steps:
1. Enter the monitor number, and then press the MON key.
2. Enter 999999, and then press the CAM key. A blue raster screen appears on the monitor.
NOTE: The default password for operator 1 is 0101; operator 2 is 0202; operator 3 is 0303; and so on. These numbers are defined in the
Operator PIN field in CM9700-MGR.