Pelco Manual C2407M-G (5/03) [ 5 ]
CONDUIT PLUG
CONCRETE WALL
OR CEILING
MOUNTING
HARDWARE
(NOT SUPPLIED) BASE
SET SCREW
8-32 X .750 FLAT HEAD
SCREW (SUPPLIED)
8-32 X .375 PAN HEAD
SCREW (SUPPLIED)
WALL OR
CEILING
ADAPTER PLATE
BASE
4S ELECTRICAL
BOX
SCREW (SUPPLIED);
SEE TEXT FOR SIZE
WALL OR
CEILING
401 OR 404
PLASTER RING
BASE
4S ELECTRICAL
BOX

Mounting Directly to Concrete Wall or Ceiling

1. Attach the base to the wall or
ceiling (hardware not supplied).
2. Do one of the following:
a. Not Using Side Conduit
Opening - Verify the set screw
and side conduit cover are tight.
OR
b. Using Conduit to Side Opening - Loosen
the set screw and remove the conduit plug.
3. Install a 3/4-inch (1.91 cm) conduit fitting and tighten the set screw.
4. Pull video and power wires into the base.

Mounting to a 4S Electrical Box

1. Attach the ICS100-AP adapter
plate (not supplied) to the 4S box
with the two 8-32 x .750-inch flat
head screws.
2. Pull video and power wires
into the base, and attach the
base to the adapter plate with
the three 8-32 x .375-inch pan
head screws.

Mounting to a Plaster Ring

Pull video and power wires into the
base, and attach the base to the
plaster ring.
Use the two 8-32 x .750-inch
pan head screws to attach the
base to a 401 plaster ring.
Use the three 6-32 x .750-inch
pan head screws to attach the
base to a 404 plaster ring.

2 Connect Video and Power

1. Connect the video cable.
2. Depending on the input voltage, connect either the 12 VDC or 24 VAC input power wires to
the appropriate positions on the terminal block inside the base.
3.
12 VDC Operation Only –
The camera is set for 24 VAC
operation at the factory.
For 12 VDC operation remove
the jumper from the 24 VAC
position and install it on the
12 VDC position.
24 VAC JUMPER
12 VDC JUMPER
VIDEO
CONNECTOR
HEATER
CONNECTOR
POWER
TERMINAL
1093