28 C2444M-C (1/04)
<Presets>
The Spectra III SE dome system has 80 programmable preset positions. Each preset can be
programmed to use pan, tilt, and all programmable camera settings.
The presets are numbered 1-32 and 35-82. Presets 33 and 34 are fixed commands that cannot be
programmed. Preset 33 is the “flip” command, which will pan the dome drive 180 degrees.
Preset 34 is the “pan zero” command, which will direct the dome drive to the factory-determined
zero reference point.
Use the following steps to program a preset.
1. Select the preset number:
a. Use the joystick to position the cursor beside PRESET NUMBER. Press Iris Open.
The cursor moves to the right.
b. Move the joystick up or down to view selections. Press Iris Open to enter selection.
2. Edit the preset label:
a. Use the joystick to position the cursor beside EDIT PRESET LABEL.
b. Press Iris Open. The following appears on the monitor:
c. Use the joystick to position the cursor beside a character. Press Iris Open to enter
selection. To clear a character, position the cursor beside BACKSPACE, and then press Iris
Open.
d. When label is completed, move the cursor to OK. Press Iris Open to return to the
Preset menu.
BACK
EXIT
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<ALERT>*
<CLEAR>
<PASSWORD>
DOME SETTINGS
LABEL FOR PRESET
PRESET NUMBER
------
1234567890 OK
ABCDEFGHIJ CANCEL
KLMNOPQRST
UVWXYZ.,-/ SPACE
abcdefghij BACKSPACE
klmnopqrst
uvwxyz*;:
EXIT
SPECTRA III
LANGUAGE ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
PRESET NUMBER 1
* * * PRESET NOT DEFINED * * *
<EDIT PRESET LABEL>
<EDIT PRESET SCENE>
<EDIT CAMERA SETTINGS>
<CLEAR PRESET>
<CLEAR CAMERA SETTINGS>
BACK
EXIT
REFERENCE INFORMATION
AZIMUTH -
ELEVATION -
ZOOM RATIO -
CUSTOM CAMERA SETTINGS -
PRESETS
* This setting only applies to
Pressurized Spectra III SE dome
systems with software version
1.25 or higher.