16 C2487M-A (4/05)
ZOOM LIMIT
Zoom limit allows the user to define a limitation on the amount of telephoto zoom. The default
setting is 144X.
Cameras with 180X zoom (18X optical zoom and 10X electronic zoom) can be set for 18X, 32X,
72X, 144X, or 180X.
ZOOM SPEED
Zoom Speed allows the user to define how fast the dome will go from full wide zoom to the 18X
optical zoom. The default setting is MEDIUM.
Available settings for zoom speed include the following:
HIGH 2. seconds
MEDIUM (default) 4.1 seconds
LOW 5.7 seconds
NOTE: When using the HIGH setting, the image may be out of focus until zooming stops.
LOW LIGHT LIMIT
Low light limit is the maximum duration, in fractions of a second, that the electronic shutter will
remain open in low light conditions. The default setting is 2.
Settings include the following:
2 = 1/2 second 8 = 1/8 second 30 = 1/30 second
4 = 1/4 second 15 = 1/15 second 60 = 1/60 second
BACK
EXIT
AUTO FOCUS ON
ZOOM LIMIT X144
ZOOM SPEED MEDIUM
LOW LIGHT LIMIT 2
IR CUT FILTER AUTO
AUTO IR LEVEL DUSK
<ADVANCED SETTINGS>
CAMERA
BACK
EXIT
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<ALERT>*
<CLEAR>
<PASSWORD>
DOME SETTINGS
EXIT
SPECTRA III
LANGUAGE ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
*This setting only applies to
Pressurized Spectra III dome
systems with software version
1.27 or higher.