Pelco c2626M manual Autonegotiation is enabled by default, Flow control is disabled by default

Models: c2626M

1 24
Download 24 pages 43.08 Kb
Page 11
Image 11

Using the TX Mode switch for a particular port, you can do the following:

Enable autonegotiation or select (force) a specific data rate and duplex mode:

Enabling autonegotiation allows the SX8205R module to automatically negotiate with the device to which the port is connected for data rate and duplex modes of operation: 10 Mbps or 100 Mbps data rate and half-duplex or full-duplex mode. The highest common denominator of operational modes is automatically selected.

Autonegotiation is enabled by default.

If autonegotiation is not desired, you can select a specific data rate and duplex mode:

Data rate configuration allows you to select 10 Mbps or 100 Mbps.

Duplex mode configuration allows you to select half-duplex mode or full-duplex mode.

Enable or disable flow control. Flow control controls data transmission at the sending device to avoid overfilling buffers and losing data at the receiving device. When the buffers on the receiving device are full, a message is sent to the sending device to suspend the transmission until the data in the buffers has been processed.

NOTE: For time-sensitive data applications (for example, video and audio applications), it is recommended that flow control be disabled.

Flow control is disabled by default.

With the SX8205R module powered off, set each TX Mode switch to the desired modes of operation. Refer to Table A for TX Mode switch settings and corresponding 10BASE-T/100BASE-TX port modes of operation. Note that each 10BASE-T/100BASE-TX port operates independently of one another; therefore, each port can be set to different modes of operation as appropriate.

 

 

 

Table A. TX Mode Switch Settings

 

 

 

 

TX Mode

 

 

 

Switch Position

 

 

10BASE-T/100BASE-TX Modes of Operation

 

 

0

Auto Neg/Dis FC: Enables autonegotiation between 10 Mbps and

 

100

Mbps and between half-duplex and full-duplex modes, disables

 

flow control (default setting)

 

 

 

1

100

FD/Dis FC: Selects 100 Mbps full-duplex, disables flow control

 

 

 

2

100

HD/DIS FC: Selects 100 Mbps half-duplex, disables flow control

 

 

 

3

10

FD/Dis FC: Selects 10 Mbps full-duplex, disables flow control

 

 

 

4

10

HD/Dis FC: Selects 10 Mbps half-duplex, disables flow control

 

 

5

Auto Neg/En FC: Enables autonegotiation between 10 and 100 Mbps

 

and between half-duplex and full-duplex modes, enables flow control

 

 

 

6

100

FD/En FC: Selects 100 Mbps full-duplex, enables flow control

 

 

 

7

100

HD/En FC: Selects 100 Mbps half-duplex, enables flow control

 

 

 

8

10

FD/En FC: Selects 10 Mbps full-duplex, enables flow control

 

 

 

9

10

HD/En FC: Selects 10 Mbps half-duplex, enables flow control

 

 

 

 

NOTE: Switch positions 0-4 disable flow control. Positions 5-9 enable flow control.

C2626M (2/07)

11

Page 11
Image 11
Pelco c2626M Autonegotiation is enabled by default, Flow control is disabled by default, Table A. TX Mode Switch Settings