CONNECTIONS

Connections to the SX8205R module are made on the rear panel of the module (refer to Figure 6).

POWER/ALARM CONNECTION

FOR RACK-MOUNTED MODULE

POWER CONNECTION

FOR STAND-ALONE MODULE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

Figure 6. SX8205R Module Connections

As illustrated in Figure 6, SX8205R module connections consist of the following:

Power connection

NOTES:

A 12 VDC or 24 VAC power supply can be used to power the module when used as a stand-alone unit. A 12 VDC power supply is provided. If a 24 VAC power supply is used, the power supply must be a Listed Direct Plug-In Power Unit marked as Class 2 and rated as 24 VAC, 0.50 A (minimum output).

In extreme temperature conditions, it is recommended that an industrial-rated outdoor power supply such as the Pelco WCS1-4 power supply be used.

10BASE-T/100BASE-TX connections

NOTES:

Use Cat5e or a higher category of cable to connect to a 10BASE-T/100BASE-TX port. Cable length must not exceed 328 feet (100 meters).

The 10BASE-T/100BASE-TX ports are auto MDI/MDI-X ports; therefore, either a straight-through or crossover cable can be used. The ports automatically detect the cable type that is used. Refer to Appendix. RJ-45 Connector Pinouts on page 22 for pinout information.