Table C. Troubleshooting with Rear-Panel Indicators (Continued)

Indicator Color

Meaning

Possible Cause

 

Corrective Action

 

 

 

 

RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Collision) (Continued)

 

 

 

 

Green

Port is set to

If 100BASE-TX full-duplex

 

100BASE-TX full-

 

operation is desired, no action

 

duplex mode.

 

is required. If 100BASE-TX full-

 

 

 

duplex operation is not

 

 

 

desired, refer to Setting

 

 

 

10BASE-T/100BASE-TX Port

 

 

 

Modes of Operation on

 

 

 

page 10 for information.

 

 

 

 

Flashing green

Port is set to

Normal or excessive colli-

If a normal collision occurs, no

 

100BASE-TX half-

sions occur on a half-duplex

action is required.

 

duplex mode and

link.*

If a problem with the network

 

network collision

 

exists due to excessive

 

has occurred.*

 

collisions, do any of the

 

 

 

following as appropriate:

 

 

 

If half-duplex mode is not

 

 

 

required, set the TX Mode

 

 

 

switch to full-duplex mode

 

 

 

by means of autonegotia-

 

 

 

tion or by forcing the mode

 

 

 

(refer to Setting 10BASE-T/

 

 

 

100BASE-TX Port Modes of

 

 

 

Operation on page 10 for

 

 

 

information).

 

 

 

If half-duplex mode is

 

 

 

required, do any of the

 

 

 

following as applicable:

 

 

 

Replace cable if it is

 

 

 

 

defective or if it is not

 

 

 

 

the proper cable type.

 

 

 

 

Use Cat5e or higher

 

 

 

 

cable.

 

 

 

Ensure that cable is the

 

 

 

 

proper length. Cable

 

 

 

 

length must not exceed

 

 

 

 

328 feet (100 meters).

 

 

 

Replace the network

 

 

 

 

interface card (NIC) if it

 

 

 

 

is defective or if it is

 

 

 

 

incompatible.

 

 

 

Segment the network.

 

 

 

 

(Continued on next page)

C2626M (2/07)

19