Pelco C2946M operation manual Mount, Power, Video, DC Iris Level Adjustment

Models: C2946M

1 6
Download 6 pages 41.98 Kb
Page 4
Image 4

MOUNT

The C10CH Series camera can be mounted from either the top or bottom, depending on the type of camera mount used in your installation. Use a standard 1/4-20 screw. The maximum thread depth is 0.25 inches (6.4 mm).

POWER

Connect 12 VDC or 24 VAC power to the back of the camera using the supplied terminal block. Use a Class 2 isolated power source for the C10CH camera that can supply 12 VDC ±15% or 24 VAC ±15%, 50/60 Hz. Maximum power consumption is approximately 3.5 watts.

C10CH-7X Camera Only

The C10CH-7X camera uses a power main supply of 220 to 240 VAC, 50 Hz. This main supply must also have a minimum rating of 50 mA.

CAUTION: Unplug the power cord during installation.

VIDEO

Connect a coaxial video cable to the BNC connector on the back of the camera.

DC IRIS LEVEL ADJUSTMENT

Select this option to adjust the electronic properties of the DC drive auto iris lens to the auto iris electronic properties of the camera. Perform this procedure before using the camera or each time you change the lens.

To perform this procedure:

1.Focus the camera (refer to Lens Focus).

2.Aim the camera at a bright, flickerless scene.

3.Select DC IRIS LEVEL from the MAIN MENU.

4.Adjust the DC IRIS LEVEL value (for the best image). The range is -20 to 20. The default setting is -4.

5.Press the center of the button to save the value.

6.Exit the MAIN MENU.

Page 4
Image 4
Pelco C2946M operation manual Mount, Power, Video, DC Iris Level Adjustment