Table B. Fiber Optic Cable Types
Spectra Model | Cable Type | Connector |
|
|
|
Single mode (PRS models) | 9/125 μm cable | ST type |
|
|
|
Multimode (PRM models) | 62.5/125 μm cable | ST type |
|
|
|
Table C. 24 VAC Wiring Distances
The following are the recommended maximum distances for 24 VAC applications and are calculated with a
|
| Wire Gauge |
| ||
Total VA |
|
|
|
| |
20 AWG | 18 AWG | 16 AWG | 14 AWG | ||
| |||||
| (0.5 mm2) | (1.0 mm2) | 1.5 mm2) | (2.5 mm2) | |
|
|
|
|
| |
73 | 39 ft | 62 ft | 98 ft | 156 ft | |
| (12 m) | (19 m) | (30 m) | (48 m) | |
|
|
|
|
|
NOTES:
•Input power for the dome is 24 VAC only. Power consumption is 73 VA per dome.
•Use a 24 VAC transformer with a minimum of 100 VA.
.
Table D. UTP Wiring Distances
Receiver | Maximum Distance |
|
|
Active | 0 to 3,000 ft |
(video only) | (0 to 914.4 m) |
|
|
Passive | 0 to 750 ft |
(video, Coaxitron®, and | (0 to 228.6 m) |
Pelco |
|
|
|
NOTE: As a minimum, UTP requires Cat5,
10 |