Pelco C3422M-B manual Spectra Model, Cable Type, Connector, Wire Gauge, Receiver

Models: C3422M-B

1 20
Download 20 pages 63.31 Kb
Page 10
Image 10

.

Table B. Fiber Optic Cable Types

Spectra Model

Cable Type

Connector

 

 

 

Single mode (PRS models)

9/125 μm cable

ST type

 

 

 

Multimode (PRM models)

62.5/125 μm cable

ST type

 

 

 

Table C. 24 VAC Wiring Distances

The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10-percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.)

 

 

Wire Gauge

 

Total VA

 

 

 

 

20 AWG

18 AWG

16 AWG

14 AWG

 

 

(0.5 mm2)

(1.0 mm2)

1.5 mm2)

(2.5 mm2)

 

 

 

 

 

73

39 ft

62 ft

98 ft

156 ft

 

(12 m)

(19 m)

(30 m)

(48 m)

 

 

 

 

 

NOTES:

Input power for the dome is 24 VAC only. Power consumption is 73 VA per dome.

Use a 24 VAC transformer with a minimum of 100 VA.

.

Table D. UTP Wiring Distances

Receiver

Maximum Distance

 

 

Active

0 to 3,000 ft

(video only)

(0 to 914.4 m)

 

 

Passive

0 to 750 ft

(video, Coaxitron®, and

(0 to 228.6 m)

Pelco V-Sync)

 

 

 

NOTE: As a minimum, UTP requires Cat5, 100-ohm twisted pair cable.

10

C3422M-B (3/08)

Page 10
Image 10
Pelco C3422M-B manual Spectra Model, Cable Type, Connector, Wire Gauge, Receiver

FAQ

What type of cable is recommended for single mode PRS models?

Single mode PRS models require 9/125 m cable with ST type connector.

What is the maximum distance for passive UTP wiring?

The maximum distance for passive UTP wiring is 0 to 750 ft for video, Coaxitron, and Pelco V-Sync.

What is the minimum requirement for UTP wiring?

As a minimum, UTP wiring requires Cat5, 100-ohm twisted pair cable.