Pelco C3422M-B manual Switch Settings, Special Systems

Models: C3422M-B

1 20
Download 20 pages 63.31 Kb
Page 12
Image 12
Switch Settings

Switch Settings

Special Systems WARNING: If you are using Pelco D or Pelco P protocol control, your system may not operate if the baud rate and address switches are not set correctly. The switches are set at the factory at the defaults for Pelco D protocol control (2400 baud and address 1).

Table F. Switch Settings for SW2

Special Systems

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

AD-32 Preset System

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CM9502 Setting

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vicon

Not currently available; SW2-3 is reserved for future use.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial Port Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

RS422

 

 

 

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS485, 4-Wire

 

 

 

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS485, 2-Wire

 

 

 

ON

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pelco D and Pelco P Protocol Baud Rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

2400 Baud (Default for Pelco D Protocol Control)

 

 

 

 

 

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

4800 Baud (Default for Pelco P Protocol Control)

 

 

 

 

 

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

9600 Baud

 

 

 

 

 

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video Cable Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

Coax Cable

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

UTP Cable

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dome Termination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Number

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

Terminated

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

Not Terminated

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

12

C3422M-B (3/08)

Page 12
Image 12
Pelco C3422M-B manual Switch Settings, Special Systems

FAQ

What is the default baud rate for Pelco D protocol control?

The default baud rate for Pelco D protocol control is 2400.

How do I set the address switches for my Pelco security system?

The address switches are set at the factory, but can be adjusted if needed for your specific requirements.

Is the Pelco C3422M-B compatible with Vicon systems?

The Pelco C3422M-B is not currently compatible with Vicon systems. Check the official manual for future updates.