DISPLAY SETUP

SPECTRA III

LANGUAGEENGLISH

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER

REBOOT SYSTEM

EXIT

DISPLAY SETUP

PRESET LABEL

2 (SECS)

ZONE LABEL

2 (SECS)

ZOOM

2 (SECS)

AZIMUTH/ELEVATION

2 (SECS)

DIRECTION

OFF

ALARM MESSAGE

2 (SECS)

<LABEL POSITIONS> RESTORE FACTORY DEFAULTS

BACK

EXIT

*This setting only applies to Pressurized Spectra III dome systems with software version 1.25 or higher.

Display setup allows you to program how labels are displayed on the monitor. The following labels are available:

PRESET LABEL - Identifies preset. ZONE LABEL - Identifies zone.

ZOOM RATIO - Identifies the amount of magnification.

AZIMUTH1/ELEVATION2 - Amount of pan from 0° and the amount of tilt from 0° horizontal. DIRECTION - Displays compass direction.

ALARM MESSAGE - Displays activated alarm.

A preset label is displayed when a preset is called. A zone label is displayed when the system moves into a zone. The zoom ratio label is displayed when zoom is activated. Azimuth/elevation and direction labels are displayed when pan/tilt is activated. An alarm message appears on the monitor when an alarm occurs.

The following settings are available for each label: OFF - Label is not displayed when activated.

CONSTANT - The label is continually displayed when activated.

2 SECONDS - The label is displayed for 2 seconds after activation.

5 SECONDS - The label is displayed for 5 seconds after activation.

10 SECONDS - The label is displayed for 10 seconds after activation.

1Azimuth is the pan angle from 0° to 359°.

2Elevation is the tilt position from 0° (horizon) to -90°.

Quick Programming Guide

(See page 11)

C2446M-E (11/05)

15

Page 15
Image 15
Pelco DD53TC16-X manual Display Setup