32 Pelco Manual C306M-K (4/05)

APPENDIX
NOTE:

Esprit will sense and automatically select input from Coaxitron

control signals in

either the standard or extended mode. Therefore, the DIP switches settings have no

effect on Coaxitron control signals.

Table A. Switch Settings for SW1

Baud Rate Switch Setting
SW1-1 SW1-2 SW1-3
2400 OFF OFF OFF*
4800 ON OFF OFF*
9600 OFF ON OFF*
* SW1-3 is not used; set it in the OFF position.
Switch Setting
SW1-4 SW1-5 SW1-6 SW1-7 SW1-8
OFF* Note (1) Note (2) Note (3) Note (4)
NOTES:
(1) SW1-5 OFF - For controllers that have more than 32 presets.
ON - For American Dynamics controllers (32 presets).
(2) SW1-6 OFF - For all control systems except CM9502 with variable
speed keyboards. For CM9502 with fixed speed keyboards,
set switch OFF.
ON - For CM9502 with variable speed keyboards to get
smoother joystick control.
(3) SW1-7 OFF - RS-422 transmitter is not terminated.
ON - RS-422 transmitter is terminated.
(4) SW1-8 OFF - RS-422 receiver is not terminated.
ON - RS-422 receiver is terminated.
* SW1-4 is not used; set it in the OFF position.