404 PLASTER RING INSTALLATION

NOTE: You should install the camera module into the back box before installing the back box into the cover. When installing the back box into the cover, rotate the camera module to access the mounting holes (refer to Camera Module on page 16 for more information).

1.Remove the two 8-32 x 0.375-inch Phillips pan head screws and washers (supplied) to separate the cover from the back box.

2.Pull the video and power wires into the cover.

3.Use up to three 6-32 x 0.75-inch Phillips pan head screws (supplied) or two 8-32 x 0.75-inch Phillips pan head screws (supplied) to attach the cover to an installed 404 plaster ring. Use stainless steel hardware when installing the system outdoors.

4.Connect the video cable and wires:

BNC: Connect the BNC connector from the unit to a mating BNC connector.

UTP: Connect the blue wire to Video +; connect the gray wire to Video -.

5.Connect the power wires (refer to Table E).

Table E. Power Input: 404 Plaster Ring Installation

Voltage

Red Wire

Black Wire

 

 

 

12 VDC

+

Ground

 

 

 

24 VAC

~

~

 

 

 

AC operation only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.

NOTE: Failure to connect all AC powered units in the same way will cause the cameras to be out of phase with each other, which may produce a vertical roll when switching between cameras.