AUTO IRIS LEVEL ADJUSTMENT
The electronics of the IS90-DW and IS90-CW Series Camclosures automatically adjust the camera to the
auto iris. Auto iris level adjustments are not necessary.
VERTICAL PHASE ADJUSTMENTUse this procedure for 24 VAC operation only.
When using more than one camera power supply, a brief vertical roll may occur on the monitor when
switching from one camera to another. To eliminate vertical roll, reverse the 24 VAC connections on one
camera. If both cameras are connected to the same transformer, this should solve the problem. If the
problem persists, adjust the phase control by synchronizing, or line-locking, the cameras to one another.
NOTE: When adjusting vertical phase, line sync (SW1-2) must be set to ON for AC line lock.
Adjusting Vertical Phase
You may need two people when synchronizing the cameras: one person at the camera and the other at the
monitor to observe the vertical roll and the effect of any camera adjustments.
To synchronize the cameras:
1. Choose a reference camera to which all other cameras will be phased.
2. Select the camera to synchronize. Use the phase adjustment control (R7) to synchronize the camera
to the reference camera (refer to Figure15 on page 24). Turn R7 clockwise to increase vertical
phase; turn R7 counterclockwise to decrease vertical phase.
3. Each time an adjustment is made, switch back and forth between the camera you are adjusting and
the reference camera. Repeat this process as many times as necessary until the roll between the
cameras is no longer noticeable.
4. Adjust the phase of all other cameras by repeating steps 2 through 3. Always adjust to the reference
camera selected in step 1.
NOTE: The preferred method for camera phase adjustment is to use a dual trace oscilloscope to align the
vertical sync pulses of the reference camera to the selected camera(s).
BLEMISH DETECTION
If small white or color spots appear in the video image, one or more pixels on the camera imager may be
defective. (This condition is common for both CCD and CMOS imagers.)
DW and CW Series cameras have auto iris lenses and automatically detect and correct defective pixels
during startup. Manual pixel correction is not available.