6.Attach the back box to the mounting surface:

If you have access behind the ceiling/wall (refer to Figure 6 on page 13):

(1)Place the adapter plate on the inside of the ceiling/wall.

(2)Attach the back box to the ceiling/wall with two 10-32 x 1.50-inch Phillips pan head self-tapping screws (supplied).

If you do not have access behind the ceiling/wall access, use 3-16 toggle bolts (not supplied; refer to Figure 8).

BACK

BOX

CEILING/

WALL

3-16 TOGGLE BOLTS

(NOT SUPPLIED)

Figure 8. In-Ceiling Installation to a Fixed Ceiling/Wall

SURFACE INSTALLATION: 4S STANDARD ELECTRICAL BOX

1.Attach the adapter plate (supplied) to the 4S box with two 8-32 x 1.00-inch Phillips pan head screws (supplied; refer to Figure 9 on page 16).

2.Pull the video and power wires through the adapter plate.

3.Connect the video cable and wires:

BNC: Connect the BNC connector from the unit to a mating BNC connector.

UTP: Connect the blue wire to Video +; connect the gray wire to Video -.

4.Connect the power wires (refer to Table D).

Table D. Power Input: Surface, 4S Standard Electrical Box Installation

Voltage

Red Wire

Black Wire

 

 

 

12 VDC

+

Ground

 

 

 

24 VAC

~

~

 

 

 

AC operation only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.

NOTE: Failure to connect all AC powered units the same way will cause the cameras to be out of phase with each other and may produce a vertical roll when switching between cameras.

C3425M-E (1/09)

15

Page 15
Image 15
Pelco IS90 manual Surface Installation 4S Standard Electrical BOX, In-Ceiling Installation to a Fixed Ceiling/Wall