Pelco PV130 RS-422 installation instructions Description, Installation, Connection Diagram

Models: PV130 RS-422

1 2
Download 2 pages 18.93 Kb
Page 1
Image 1
C1919M-C (11/00)

®

3500 Pelco Way,

Clovis, CA 93612-5699

USA

In North America & Canada:

Tel (800) 289-9100

FAX (800) 289-9150

DataFAX (800) 289-9108

International Customers:

Tel +1(559) 292-1981

FAX +1(559) 348-1120

DataFAX +1(559) 292-0435

PelcoEurope BV

Dillenburg Center

Dillenburgstraat 5F

5652 AM Eindhoven

The Netherlands

Tel +31(40) 251-9870

FAX +31(40) 251-9835

Pelco Online

www.pelco.com

C1919M-C (11/00)

PV130 RS-232/422 Converter Kit

Installation Instructions

DESCRIPTION

The PV130 RS-232/422 Converter Kit provides a bi-directional electrical interface between RS-232 and RS-422 data ports.

The plug-in power supply, included in this package, allows the PV130 to communicate serial port data over wire pairs for distances up to 4,000 feet (1,219 m) on the RS-422 side.

User must supply all necessary cable between converter and receivers.

Contents of this package:

 

Qty

Description

Part number

1

RS-232/422 Converter

EE03-1235-5430

1

12 VDC power supply, 1.2W

PS04-1000-0112

INSTALLATION

Refer to Figure 1 during the installation instructions that follow.

Control Connections

1.Attach the 9-pin side of the converter to the computer’s serial port or to the COM 2 port on the PelcoVision Transmitter.

2.Wire the receiver’s RX- and RX+ terminals to the converter’s TX- and TX+ terminals. If neces- sary, use a 120-ohm resistor to terminate the line at the receiver’s RX- and RX+ terminals.

NOTE: Proper operation of an RS-422 circuit requires that the active devices at both ends of the communications facility be referenced to a common ground, such as earth. If the ground is established through a metallic conductor, it is recommended that 100-ohm resis- tors be placed in series with the ground connection at each end (refer to Figure 2). This will limit any currents that may be caused by other ground paths.

Connecting the Power Supply (See Figure 1)

1.Connect the black/white stripe wire to the converter’s +12 VDC terminal and the solid black wire to the GND terminal.

2.Plug the power supply into a 115 VAC wall socket or power strip.

FEMALE DB9 TO TRANSMITTER Installation Instructions COM 2 PORT

+12 VDC

*12 VDC POWER SUPPLY

GND

*IF NECESSARY

PV130 CONVERTER

DESCRIPTION RX +

INSTALLATION RX -

TO RECEIVER(S)

TX- TX+ RX- RX+ GND +12 VDC

Figure 1. Connection Diagram