INSTALLATION FOR OCIA INTERFACE

1.Turn off the host system.

2.Connect the MVC cable to the 2nd jack down from the top of the MS7600.

3.Connect the other end of the MVC cable to the host.

Before continuing verify that the MVC cable is connected to the appropriate interface jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner.

Manufacturers Note:

Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur.

4.Turn on the host system.

5.Scan the Load OCIA Defaults bar code to configure the MS7600 for OCIA communication.

Figure 13: OCIA, Interface

Load OCIA Defaults

³ 9 9 9 9 9 3

For additional communication options for OCIA interfaces refer to the MetroSelect Programming Guide (MLPN 00-02407B).

Caution:

To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950.

To maintain compliance with standard CSA C22.2 No. 60950-00/UL 60950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.