MAINTENANCE

Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning.

For the MS7600 glass window:

1.Spray glass cleaner onto lint free, non-abrasive cleaning cloth.

2.Gently wipe the scanner window.

For the MS7600 red window:

1.Use mild soap and water with lint free, non-abrasive cleaning cloth.

2.Gently wipe the scanner window.

EAS DEACTIVATION ANTENNA

SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. Metrologic recommends end users program the MS7600 to the Fixed Low-Density depth of field, so that the unit does not scan out beyond the deactivation range.

Unit #

CheckPoint Recommended

MS7600 Depth of Field

Switch Bank Settings

Settings

 

MS7620

1, 2, 3, 4, 5, on SW1 & SW2

Fixed Low Density*

 

 

 

MS7625

1, 2, 3, 4, 5, on SW1 & SW2

Fixed Low Density*

 

 

 

*Note: Minimum element width changes to 6.8 mil when in this mode.

EAS Cable

Connector

EAS Cable

MLPN 49-00298

Figure 22: EAS Cable and Connector

Contact Checkpoint Systems directly for additional EAS support.