TROUBLESHOOTING GUIDE (CONTINUED)

SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

 

 

 

 

 

 

 

 

Add some intercharacter delay

Characters are

Intercharacter delay

to the transmitted output by

needs to be added to

using the MetroSelect®

being dropped.

the transmitted output.

Programming Guide

 

 

 

(MLPN 00-02407A-1 & -2).

 

 

 

Aux port operation with any interface

 

Trouble with the

 

Refer to the user guide provided

Secondary

 

 

with the secondary scanner.

Scanner.

 

 

 

 

 

 

 

 

 

Secondary

Scanner powers up but data is not relayed to the host.

Cable [MLPN 54-54667]

Ensure Secondary scanner is

may not be connected

connected to the MS7600 com

to the proper port.

port marked “Aux” port.

 

 

 

* The MS7600 must be

 

programmed to enable the

The “Aux” com port

“Aux” port.

may not be operating

The auxiliary input port’s data

properly.

format must match the main

 

output format of the secondary

 

scanner.

 

 

*Use MetroSet®.

For the Auxiliary interface, choose “HoloTrak Decode”. All remaining parameters will be automatically chosen.

USB Only

The scanner Powers up ok, scans ok but does not communicate.

The USB Port is not operating correctly.

Check that the scanner is programmed for USB operation.

Check that the host’s USB port is enabled.

 

 

 

When configured

 

Unplug & plug USB cable at host

 

end.

as USB scanner

USB port is not

razz tone & 3

operating correctly.

Contact a Metrologic

LED flashes.

 

 

representative if error continues.

 

 

 

 

 

 

 

 