16 Pelco Manual C2419M-A (5/00)
LIMIT STOPS
Main Menu
<Camera>
<Line Sync>
<Power Up>
<Aux>
<Alarms, Zone Blank>
<Other>
EXIT
Other Menu
Auto flip On
Proportional pan On
Limit stops On
Park time minutes 0
Scan speed deg/s 25
Pattern length 6 min
Exit
There are two types of limit stops:
Manual limit stops - A manual (joystick) pan operation stops when a limit stop is reached.
Scan limit stops - The dome reverses direction during random, frame, or auto
scanning when a limit stop is reached.
Limit stops are controlled by software. To set limit stops:
1. Turn on the limit stop mode.
2. Program the limit stops.
TURNING LIMIT STOPS ON OR OFF
To change the limit stop mode:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Other.
3. Press the Iris Open button to enter the Other menu.
4. Position the cursor (>) beside Limit Stops.
5. Press the Iris Open button. The cursor moves to the right, beside the word On or Off.
6. Move the joystick up or down to toggle between On and Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
PROGRAMMING LIMIT STOPSManual Limit Stops
Refer to the documentation for your control system for programming presets, and then do
the following:
1. Make sure limit stops are turned ON, and then exit the menu.
2. Push the joystick left until you reach the limit you want the camera to go to on the left.
3. Program preset 90 (23).
4. Push the joystick right to the limit you want the camera to go to on the right.
5. Program preset 91 (24).
Setting presets 90 (23) and 91 (24) to the same point disables manual limit stops.
Scan Limit Stops
Refer to the documentation for your control system for programming presets, and then do
the following:
1. Make sure limit stops are turned ON, and then exit the menu.
2. Push the joystick left until you reach the limit you want the camera to go to on the left.
3. Program preset 92 (25).
4. Push the joystick right to the limit you want the camera to go to on the right.
5. Program preset 93 (26).
Setting presets 92 (25) and 93 (26) to the same point disables scan limit stops.
NOTE:

Programming

preset 90 (23) disables the

manual limit stops until

preset 91 (24) is set.

NOTE:

On power-up, the

auto scan tilt angle will be

whatever angle the camera

was at when the right scan

limit was set.