Pelco Manual C2419M-A (5/00) 19

This feature lets the dome resume a desired condition following power-up. The menu
includes the following choices.
Default - On power-up, the dome goes through a configuration cycle and stops at
zero reference, showing “Configuration Done,” address, and mode
settings on the screen.
Park - The dome moves to preset 1 when the power-up sequence finishes.
The only text on the screen is the preset label (if any is programmed).
Scan Auto - The dome initiates scan mode when the power-up sequence finishes.
Again, there is no text.
Scan Frame - The dome initiates a frame scan when the power-up sequence finishes.
Scan Rand - The dome initiates a random scan when the power-up sequence finishes.
Full Pat - The dome initiates its programmed pattern when the power-up sequence
finishes. The length can be set to 1.5, 3, or 6 minutes.
Half Pat 1 - The dome initiates the first half-pattern when the power-up sequence
finishes. The length can be set to .75, 1.5, or 3 minutes.
Half Pat 2 - The dome initiates the second half-pattern when the power-up sequence
finishes. The length can be set to .75, 1.5, or 3 minutes.
The default setting is Default.
To select the power-up mode:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Power Up Mode.
Main Menu
<Camera>
<Line Sync>
<Power Up>
<Aux>
<Alarms, Zone Blank>
<Other>
EXIT
Power-Up Menu
Power Up Default
Exit
POWER-UP MODEPATTERN LENGTH
CAUTION:

If the

length is changed,

all patterns that

were stored are erased.

Main Menu
<Camera>
<Line Sync>
<Power Up>
<Aux>
<Alarms, Zone Blank>
<Other>
EXIT
Other Menu
Auto flip On
Proportional pan On
Limit stops On
Park time minutes 0
Scan speed deg/s 25
Pattern length 6 min
Exit
The Spectra II dome can do the following:
One full pattern - 1.5, 3, or 6 minutes long.
or
Two half patterns - .75, 1.5, or 3 minutes long.
This pattern can consist of any standard pan and tilt or lens command. Presets, flip, and
turbo are not allowed in a pattern. Zone scan can be enabled while running a pattern.
To set the pattern length:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Other.
3. Press the Iris Open button to enter the menu entitled Other.
4. Position the cursor (>) beside Pattern Length.
5. Press the Iris Open button. The cursor moves to the right, beside the number of
minutes (1.5, 3, or 6).
6. Move the joystick up or down to toggle through the number of minutes (1.5, 3, or 6).
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.