Pelco Manual C2419M-A (5/00) 7
AUXILIARY OUTPUTS
An AUX 1 command from the controller will activate the relay in the dome and operate the
device that is connected to the relay. The relay will remain latched until a clear command is
issued.
An AUX 2 command from the controller will place a ground at the output of AUX 2 to oper-
ate the device that is connected to it. The output will remain latched until a clear command
is issued.
The output relay can also be programmed so that it is activated when any alarm input is
activated. When latching (toggling) is selected on the programming menu, giving the AUX 1
command from the controller changes the state of the AUX (for example, if it was on, this
turns it off.) The clear command from the controller will turn the AUX off in the latching or
toggle mode.
PARK
If the dome does not receive any commands for a specified period of time (refer to

Park

Time Minutes

in the
Programming
section), the dome will go to preset 1 and park. If the
time specified is zero, or if preset 1 has not been programmed, the dome will not park.
The default is zero minutes.
AUTO IRIS
If auto iris is in the auto mode, it remains that way until you manually open or close the iris.
The dome will return to auto iris when it is panned or tilted more than 15 degrees. If there is
not enough light for a good picture when the iris is wide open, you can increase the gain of
the camera to improve the picture.
To increase the gain:
1. Hold down the Iris Open button until the iris is wide open.
2. Release the button.
3. Within one second, hold down the button again. This starts increasing the camera
gain. Hold down the button until a desirable picture is obtained or the maximum gain is
reached.