INTERFACING WITH A PC
1.Attach the end of the serial cable that is not connected to the camera’s detachable connector to your PC’s serial port.
2.Proceed to Configuration on page 15; follow all steps in the Configuration section before completing the bench setup using the remaining steps in this section.
3.After completing the camera configuration, remove the serial cable from the detachable connector.
REASSEMBLE THE ENCLOSURE
1.Place the supplied desiccant bag at the back of the enclosure.
2.Make sure that the lubricated
WARNING: The
3.Reinstall the camera assembly.
a.Slide the camera assembly into the front of the enclosure, making sure that the bracket tongue on the underside of the camera assembly is aligned with the groove on the inside bottom of the enclosure.
b.Push the front plate snugly against the enclosure to ensure that the
c.Use the supplied
4.Reattach the ground cable to the ground stud on the inside of the enclosure’s back plate.
5.Reinstall the enclosure sled.
a.Slide the enclosure sled into the back of the enclosure.
b.Push the back plate snugly against the enclosure to ensure that the
c.Use the supplied
6.Gently pull the cables coming out of the gland connectors on the back plate to eliminate any cable slack inside the enclosure.
7.Tighten both of the gland connectors to create an appropriate seal.
12 |