24 Pelco Manual C651M (7/99)6.7 RECORDING SET UP MENU
ALARM REC Sets the alarm recording mode. When you turn the JOG dial, the
MODE display switches in the following order: 2H, 6H, L18H, 2H.
(Refer to Section 8.3.3 for programming instructions.)
ALARM REC Sets the length of the alarm recording period. When you turn the
DURATION JOG dial, the display switches in the following order: 1M
(minute), 2M, 5M, 10M, MAN1, MAN2, 15S (second), 30S, 45S,
1M. (Refer to Section 8.3.3 for programming instructions.)
EMERGENCY REC Sets the emergency recording mode, as follows:
• OFF – Starts alarm recording when the alarm signal is
received during recording.
•ON – Starts alarm recording when the alarm signal is
received, not only during recording but also when the
power is OFF or when the tape is stopped.
Refer to Section 8.3.3 for programming instructions.
6.8 REAR TERMINAL MENU
CALL OUT Sets the call signal output at the end of the tape. Turns on or off
the signal that comes from the CALL terminal when the end of
the tape is reached during recording. If any problems occur
during recording, a call signal is output from the CALL terminal
on the rear panel regardless of the CALL OUT setting.
WRNG•TAPE END – A signal is output at the end of the
tape or when a malfunction occurs.
WRNG•REMAIN – The signal is output when a malfunc-
tion occurs in the VCR or when the tape has about three
minutes left in 2H mode.
WRNG – When a malfunction occurs in the VCR during
recording, a call signal is output.
CALL OUT is used in conjunction with TAPE END (First Time
Set Up menu) to determine when the call signal is output, as
shown in Table B.

Figure 12. Recording Set

Up Menu

<RECORDING SET UP>
ALARM REC MODE 2H
ALARM REC DURATION 1M
EMERGENCY REC OFF
NOTE:

Set the ALARM REC DU-

RATION to MAN2 to use with the

MX4000 Series Genex™ Multi-

plexer.

NOTE:

When using the MX4000

Series Genex™ Multiplexer, make

sure the EMERGENCY REC set-

ting is ON if the VCR is to record

alarms only.

Figure 13. Rear Terminal

Menu

<REAR TERMINAL>
CALL OUT WRNG•TAPE END
CLOCK OUT REC-1
MODE OUT REC
REC IN SERIES

Table B. Call Out/Tape End

CALL OUT
Setting
TAPE END
Setting WRNG•TAPE END WRNG
STOP Outputs a call signal at the
end of the tape
Outputs a call signal at the
end of the tape for 2 seconds
Outputs a call signal at the
end of the tape
When a malfunction occurs in the VCR
during recording, a call signal is output.
REWIND
REPEAT
ALARM
• PROT
When there are no
alarm recordings
during recording
WRNG•REMAIN
Outputs a call signal three minutes
before the end of the tape
Same as above
Same as above
Same as above
Same as above
Same as above
Same as above
Same as above
Same as above
Same as above Same as above
When there are no
alarm recordings
during recording