26 Pelco Manual C651M (7/99)
POWER LOSS Turn the SHUTTLE ring to the right and the words POWER
LIST CLEAR LOSS LIST CLEAR will be displayed. When you turn the
SHUTTLE ring to the left, the list will be cleared. Turn the
SHUTTLE ring to the right to return to the Maintenance menu.
ALARM LIST Turn the SHUTTLE ring to the right and the words ALARM LIST
CLEAR CLEAR will be displayed. When you turn the SHUTTLE ring to
the left, the list will be cleared. Turn the SHUTTLE ring to the
right to return to the Maintenance menu.
6.10 FIRST TIME SET UP MENUTAPE END Sets the VCR’s state of operation when the tape runs out during
recording.
• STOP – The tape stops. “End” appears on the fluorescent
display and “Tape End” on the monitor. When CALL OUT
is set to WRNG•TAPE END, a call signal is output from the
CALL terminal.
• REWIND – Rewinds the tape to the beginning and stops
(except during timer recording). When CALL OUT is set to
WRNG•TAPE END, a call signal is output for two seconds
from the CALL terminal.
• REPEAT - Rewinds the tape to the beginning and re-
sumes recording.
• ALARM•PROT – (Alarm Protection) If alarm recordings
are on the tape, then the tape stops. “End” appears on the
fluorescent display and “Tape End” on the monitor. When
CALL OUT is set to WRNG•TAPE END, a call signal is
output from the CALL terminal. If there are no alarm
recordings, the tape is rewound and recording continues.
QUASI V-SYNC Sets Quasi V-Sync on or off.
•ON – Quasi V-Sync signal is inserted on the video output
signal when in the special playback modes (still, slow
motion, reverse, fast playback, speed search) and during
normal playback in L18H, 72H, or 96H modes.
• OFF - Quasi V-Sync signal is not inserted.
TAPE LENGTH Sets the tape length to match the tape so the tape remaining
indicator works correctly. Set as follows:
• T-120 – When using T-120 tape.
• T-160 – When using T-160 tape.
TIME DATE Sets the time, date, and Daylight Savings setting. Section
ADJUST 6.10.1 provides an explanation while Section 6.10.2 provides a
procedure.
6.10.1 Day And Time Display ModesDisplay Mode 1
1. Month-Day-Year
2. Hour:Minute:Second
3. Daylight Savings Time symbol or power failure symbol
4. Alarm recording number
• A 24-hour display is used: 00:00 indicates midnight; 12:00, noon;
and 15:00, 3 p.m.
• An alarm recording number is displayed during alarm recording.
Figure 15. First Time Set
Up Menu
<FIRST TIME SET UP>
TAPE END STOP
QUASI V-SYNC ON
TAPE LENGTH T-120
TIME DATE ADJUST
NOTE:
Some multiplexers may re-
quire Quasi V-Sync OFF to work
properly. With the Pelco MX4000
Series Genex™ Multiplexer, setting
Quasi V-Synch on or off has no
apparent effect on playback.
Figure 16. Display Mode 1
01-01-97 00:00:00 A0001