50 Pelco Manual C651M (7/99)
13.0 SPECIFICATIONSELECTRICAL
Power source: 100-230 VAC, 50/60 Hz. (The included power cord is
used for 120 VAC, 60 Hz)
Power consumption: Approximately 20 watts
Rating:
ALM/CALL/MODE Active: “Low” level, maximum current 50 mA
(+5 VDC)/10 mA (+24 VDC)
Non-active: Open, maximum voltage +24 VDC
SET/RST/REC Active: When terminals are short-circuited or
“Low” level voltage applied
Non-active: Open, maximum voltage +17 VDC
CLK Recording: A pulse of the frequency division ratio
selected in REAR TERMINAL menu
VIDEO
Tape format: VHS 1/2" width high-density video cassette tape
Television System: 525 lines, 60 field NTSC-type color system
Video Recording System: 4 rotary heads, azimuth helical scanning system
Luminance Signal: Frequency modulation recording
Color Signal: Low frequency conversion, sub-carrier phase shift
recording
Audio Track: 1 track
Tape Speed and Recording
Time (with T-120 cassette):
Record Mode Record Time Record Time Field (Picture) Tape Drive Audio Recording
(T-120 Tape) (T-160 Tape) Recording Rate Mode Capability
2H 2 Hrs. 2 Hrs.40 Mins. 60 Fields/Sec Continuous Yes
6H 6 Hrs. 8 Hrs. 60 Fields/Sec Continuous Yes
L18H 18 Hrs. 24 Hrs. 20 Fields/Sec Continuous (Slow) Yes
72H (EP) 78 Hrs. Not Recommended 4.6 Fields/Sec Time-lapse No
96H (EP) 102 Hrs. Not Recommended 3.5 Fields/Sec Time-lapse No
Fast Forward/Rewind Time: Approx. 140 sec. with T-120 cassette.
Horizontal Resolution: More than 350 lines (Black & White)
More than 300 lines (Color)
Audio frequency response: 70 Hz-7 kHz (2H mode)
Signal-to-Noise Ratio: Video: better than 42 dB
Audio: better than 43 dB
Alarm Recording Time: Timed: 15 sec/30 sec/45 sec/1 min/2 min/
5 min/10 min
Manual 1: Until the alarm reset switch is
switched on
Manual 2: Until the alarm set switch is
switched off
Display format:
DISPLAY MODE 1: (Month)-(Day)-(Year) (Hour) : (Minute) : (Second)
(Alarm recording no)
DISPLAY MODE 2: (Month)-(Day)-(Year) (Day of week)
(Alarm recording no)
(Hour) : (Minute) : (Second) ( Recording mode)
Display position: In any position
Timer Program: 8 programs; Daily start and stop time for one week
Battery Backup: Lasts 31 days
Elapsed Time Indicator Maximum of 89,999 hours