66 Pelco Manual C672M (2/01)
No. Commands Functions Status After Normal Explanation of Status
Execution
74 ST*#1 Set menu item to flash RC#2EX#2 Command received and carried
* : 0=OFF, 1=ON out
75 BZ*#1 Buzzer setting Same as above Same as above
* : 0=WRNG, 1=WRNG•TAPE END,
2=WRNG•REMAIN, 3=OFF
76 BR*#1 Buzzer on/off setting Same as above Same as above
* : 0=OFF, 1=ON
77 FS2#1 Inquiry about buzzer setting RC#2BZ*#2 *=Same as item 75
78 BP#1 Inquiry about buzzer status RC#2SW*#2 * : 0=OFF (not ring), 1=ON (ring)
79 OS**#1 One-shot field setting RC#2EX#2 Command received and carried
** : 01, 02, 03, 04, 05, 10, 20, 30 out
80 OF#1 Inquiry about one-shot field setting REC#2SD**#2 **=Same as item 79
81 OI*#1 One-shot interval setting RC#2EX#2 Command received and carried
* : 0=SHOT, 1=10S, 2=15S, 3=30S, out
4=45S, 5=1M, 6=2M, 7=3M
82 OI?#1 Inquiry about one-shot interval setting RC#2OI*#2 *=Same as item 81
83 AN#1 Inquiry about current alarm REC no. RC#2AN****#2 ****=0000-9999
84 AT*#1 Inquiry about alarm list RC#2AT**(1),**(2),**(3),**
(1) : Month, **(2) : Day,
* : 0=about the 1st alarm recording **(4),**(5)#2 **(3) : Year, **(4) : Hour,
1-7=about the last to 7th last alarm **(5) : Minute
recording
85 CA#1 Clearing alarm listRC#2EX#2 Command received and carried out
86 PN#1 Inquiry about current power loss list no. RC#2PN**#2 **=00-99
87 PT*#1 Inquiry about power loss list RC#2PT**(1),**(2),**(3),**
(1) : Month, **(2) : Day,
* : 0=about the 1st power loss **(4),**(5)#2 **(3) : Year, **(4) : Hour,
1=about the 2nd power loss **(5) : Minute
2=about the last power loss
88 PC#1 Clearing power loss list RC#2EX#2 Command received and carried
out
89 MI#1 Initializing the menu setting Same as above Same as above
90 HM?#1 Inquiry about the elapsed time RC#2HM*****#2 *****=hour
91 WN#1 Inquiry about warning information RC#2WN**#2 ** : Warning no.
0=no malfunction, 01=tape end,
03=video input missing,
04=clogged head, 05=reel rotation
trouble, 06=loading motor trouble,
07=capstan motor trouble,
08=drum motor trouble, 09=tape
loose, 10=switching power short
92 CA0#1 Clearing the warning “ER05” RC#2EX#2 Command received and carried out
93 RI*#1 REC IN setting Same as above Same as above
* : 0=SERIES, 1=REC-START/STOP,
2=SYNC REC
94 RI?#1 Inquiry about REC IN setting RC#2RI*#2 *=Same as item 93
95 QV*#1 Quasi v-sync setting RC#2EX#2 Command received and carried
* : 0=OFF, 1=ON out
96 QM#1 Inquiry about quasi v-sync setting RC#2QV*#2 * = 0=OFF, 1=ON
97 CL*#1 Call out setting RC#2EX#2 Command received and carried
* : 0=WRNG, 1=WRNG•TAPE END, out
2=WRNG•REMAIN
98 RL#1 Inquiry about call out setting RC#2CL*#2 *=Same as item 97
(Continued on next page)