Whole House Water Filter Tank Installation

Pelican PSE1800/PSE2000 Premium Whole House Water Filter

PSE1800-2000 Rev M

& Salt Free Water Softener/Conditioner Combo

Page 10

 

 

 

 

Whole House Water Filter Tank Installation

1. Level the Pelican Whole House Water Filter.

Table 2: Bypass Valve Fittings Notice:

If the tank is not level, lift the tank straight up 6 inches and tap it on the ground until the tank stands vertical. The bottom of the tank is round and the boot allows the tank to stand upright.

Pre-Filter

IncomingManual background

Water

Supply

INLET

UPFLOW

Whole House

Water Filter

PVC Fitting*

Outgoing

Water to

House

Manual backgroundManual background 1" NPT Assembly

Bypass Valve

DOWNFLOW

INLET

*Customer supplied,

choose appropriate connection

Figure 7

2.Determine the size and material of your incoming water supply line from the Pre-Filter System and choose the appropriate plumbing required to adapt to the 1” Male NPT Assembly.

Manual background CAUTION:

Do not over-tighten any of the fittings during installation.

Table 2: Bypass Valve Fittings

Note: The fitting below is designed with a ¼" give to allow for proper pipe alignment. It will not leak and is intended to have some flexibility.

Part

Description

Qty.

 

1" Plastic Male NPT Assembly:

1

 

V3007-04 WS1 Fitting 1" Plastic Male NPT

bag

 

Assembly (2): O-Rings (2), Split Rings

 

 

(2), and Connectors (2)

 

3.Install the fitting onto the upflow and downflow inlet sides of the Bypass Valve. Follow the diagram supplied with the fitting.

4.Connect the incoming water supply from the to the fitting on the upflow inlet side of the Bypass Valve.

5.Connect the outgoing water supply to the downflow inlet side of the Bypass Valve.

© 2013 Enviro Water Solutions, Inc.

www.pelicanwater.com

3060 Performance Circle, Suite 2, DeLand, FL 32724

(877) 842-1635